Clarke American Sanders B-2+DC Manuel De L'utilisateur page 10

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ENGLISH
EN
MAINTENANCE (cont)
The Dust Control System
Remove the dust from the bag when the bag is
full or when the effi ciency of the dust control system
decreases.
If the exhaust pipe gets an obstruction, follow this proce-
dure:
1. Remove the four screws that hold the exhaust
pipe to the housing. See fi gure 8.
2. Remove the obstruction from the exhaust pipe.
3. Install the exhaust pipe.
How to Adjust the Angle Of The Sandpaper Disc To
The Floor
The adjustment of the machine is correct when the front
part of the sandpaper disc makes contact with the fl oor.
To change the adjustment of the machine, follow
this procedure:
1. Using the special wrench, loosen the lock nut on
each caster. See (1) fi gure 9.
2. Loosen the jam nut. See (2) fi gure 9.
3. Raise or lower the casters as needed.
4. Tighten the jam nut on each caster.
5. Tighten the lock nut on each caster.
How To Replace The Light Bulb
To replace the light bulb, follow this procedure:
1. Remove the two screws that hold the light guard
to the housing. See fi gure 10.
2. Remove the light guard.
3. Remove the light bulb from the socket.
4. Install a new light bulb.
5. Put the lamp guard in position.
6. Install the two holding screws.
The Ventilation Plug
1. To clean the ventilation opening in the center of
the plug, remove the plug from the machine. With
the plug removed, also inspect the grease in the
gearbox. See fi gure 11.
-10-
FORM NO. 70896A
All manuals and user guides at all-guides.com
/
1
3
American Sanders
®
Clarke
Figure 8
2
Figure 9
Figure 10
Figure 11
Operator's Manual (EN) - American B2
1

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

07127a07096a07128a

Table des Matières