Device Information - Dimplex SI 10MER Instructions D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

12 Device Information

1
Type and order code
2
Design
2.1
Model
2.2
Degree of protection according to EN 60 529
2.3
Installation location
1
3
Performance data
3.1
Operating temperature limits:
2
Heating water flow
Cooling, flow
Brine (heat source, heating)
Brine (heat sink, cooling)
Antifreeze
Minimum brine concentration (-13 °C freezing temperature)
3.2
Heating flow / internal pressure differencial
Nominal flow according to EN 14511 at B0 / W35-30
Minimum flow
3.3
Heat output / COP
3.4
Cooling flow / internal pressure differencial
Nominal flow according to EN 14511 at B30-35 / W7-12
Minimum flow
3.5
Cooling capacity / COP
3.6
Sound power level according to EN 12102
3.7
Sound pressure levelat a distance of 1 m
3.8
Refrigerant / total filling weight
3.9
Lubricant / total filling weight
4
Dimensions, connections and weight
4.1
Device dimensions without connections
4.2
Device connections to heating system
4.3
Device connections to heat source
4.4
Weight of the transportable unit(s) incl. packing
5
Electrical Connection
5
5.1
Nominal voltage
/ fuse protection
5.2
Control voltage / Fuse protection
5.3
Nominal power consumption B0W35
5.4
Starting current with soft starter
5.5
Nominal current B0 W35 / cos
www.dimplex.de
All manuals and user guides at all-guides.com
°C
°C
°C
°C
m³/h / Pa
at B0 / W45-40
m³/h / Pa
at B0 / W55-47
m³/h / Pa
m³/h / Pa
at B-5 / W55
kW / ---
at B0 / W55-47
kW / ---
at B0 / W45-40
kW / ---
at B0 / W35-30
kW / ---
m³/h / Pa
at B30-35 / W18-23
m³/h / Pa
m³/h / Pa
at B30-35 / W7-12
kW / ---
at B30-35 / W18-23
kW / ---
at B20 / W8
kW / ---
at B20 / W18
kW / ---
at B10 / W8
kW / ---
at B10 / W18
kW / ---
dB(A)
3
dB(A)
type / kg
type / litres
4
H x W x L mm
inch
inch
kg
V / A
V / A
1
/ max. consumption kW
A
A / ---
452232.66.38 · FD 9405
SI 10MER
Reversible
IP 21
Indoors
+20 to +62 ±2
+7 to +20
2
-5
to +25
+5 to +40
Monoethylenglykol
25 %
Brine
Heating water
2,4 / 15800
1,7 / 8000
2,4 / 15800
1,7 / 8000
1,9 / 9600
1,0 / 2800
1,9 / 9600
1,0 / 2800
7,6 / 2,3
8,9 / 2,7
9,3 / 3,3
9,7 /4,3
Brine
Cooling water
2,5 / 17100
1,9 / 9500
3,0 /24700
2,3 / 14000
2,4 / 15800
1,7 / 8000
10,7 / 4,3
13,4 / 5,2
12,1 / 6,2
14,5 / 7,2
12,6 / 8,1
14,7 / 9,2
49
37
R410A / 2,0
Polylester / 1,2
805 x 650 x 462
G 1¼" a
G 1¼" a
121
1~/N/PE 230 V (50 Hz) / C25 A
1~/N/PE 230 V (50 Hz) / C13 A
2,28 / 4,05
44
10,4 / 0,95
SI 10MER
EN-11