S/ST braided
hose Lg : 1,5m
Water pressure
2 bar to 6 bar
Recommended
water T°: 50°C
WATER
Fiber gasket ¾"
F ¾" - M ½"
Fiber gasket ½"
F ½"
IMPORTANT !
Adjust the length of
suction line in order
to put the yellow
filter vertically at the
Bottom of can
1°_ Check if water pressure is ok (minimum : 2 bars, maximum : 6 bars)
2°_ Check if filter gasket is clean. (clean or replace)
3°_ Check if the succion line is correctly in the can, and if pipe is not bended or blocked
4°_ Check if tip is not blocked (clean or replace)
5°_ Check if yellow filter is clean (clean or replace)
6°_ Check if spraying gun is clean (clean or replace)
7°_ Check if check-valve is clean (clean or replace)
CLEANING or REPLACEMENT of green injector
« PROKLYN » Washing station - Troubles
F ¾"
The unit doesn't suck up product
Can product fills with water.
Injector removing
Plug
Pull
GREEN Injector
Injector replacing
C
Push
1 hole Ø10mm
Tap drilling
TROUBLES
Flat nose
plier
Gasket
TO CLEAN OR REPLACE THE INLET FILTER GASKET
1_Unscrew the nut.
2_Clean or replace the filter gasket.
3_Reassemble properly the filter gasket
Respect the orientation
2 PRODUCTS VERSION
CLEANING of check-valve
Ceramical ball
NTPOSSLB V3.4 p.9/11
GB
O ring