12 Device Information

1
Type and order code
2
Design
2.1
Degree of protection according to EN 60 529 for compact devices
and heating components
2.2
Installation location
3
Performance data
3.1
Operating temperature limits:
Heating water flow/return flow
Air
3.2
Temperature spread of heating water
(flow/return flow)
3.3
Heat output / COP
3.4
Sound power level device / outdoors
3.5
Sound pressure level at a distance of 1 m (indoors)
3.6
Heating water flow with an internal pressure differential of m³/h / Pa
3.7
Air flow rate with an external static pressure differential of m³/h / Pa
3.8
Refrigerant; total filling weight
3.9
Lubricant; total filling weight
3.10 Max. output of electric heating element
(2nd heat generator)
4
Dimensions, connections and weight
4.1
Device dimensions
4.2
Device connections to heating system
4.3
Air duct inlet and outlet (min. internal dimensions)
4.4
Weight of the transportable unit(s) incl. packing
5
Electrical Connection
5.1
Nominal voltage; fuse protection
(combined infeed HP and HG2)
5.2
Fuse protection for separate infeed: HP / HG2
5.3
Nominal power consumption
5.4
Starting current with soft starter
Nominal current A2 W35 / cos ϕ
5.5
6
Complies with the European safety regulations
7
Additional model features
7.1
Defrosting
Type of defrosting
Defrosting tray included
7.2
Heating water in device protected against icing
7.3
Performance levels
7.4
Controller internal/external
1. This data indicates the size and capacity of the system according to EN 255 or EN 14511. For an analysis of the economic and energy efficiency of the system, other parameters,
in particular the defrosting capacity, the bivalence point and regulation, should also be taken into consideration. The specified values have the following meaning, e.g. A2 / W35:
2 °C external air temperature and 35 °C heating water flow temperature.
2. The specified sound pressure level represents the free field level. The measured value can be up to 16 dB(A) higher, depending on the installation location. This value corresponds
to the operating noise of the heat pump in heating operation with a flow temperature of 35 °C.
3. See CE declaration of conformity
4. The heat circulating pump and the heat pump manager must always be ready for operation.
EN-12
All manuals and user guides at all-guides.com
°C / °C
°C
at A7 / W35
K
1
at A-7 / W35
kW / ---
1
at A-7 / W45
kW / ---
1
at A2 / W35
kW / ---
1
at A7 / W35
kW / ---
1
at A7 / W45
kW / ---
1
at A10 / W35
kW / ---
dB(A)
2
dB(A)
type / kg
type / litres
kW
H x W x L cm
Inch
L x W cm
kg
V / A
1
A2 W35
kW
A
A / ---
4
LI 9TEL
IP 21
Indoors
Up to 58 / above 18
-25 to +35
10,0
5,8 / 2,7
5,5 / 2,6
5,4 / 2,1
7,5 / 3,3
7,4 / 3,2
9,3 / 3,9
9,2 / 3,8
8,8 / 3,2
9,8 / 4,1
9,7 / 4,0
53 / 60
48,0
0,8 / 2700
1,6 / 11900
2500 / 20
R404A / 1,9
Polyolester (POE) / 1.5
6,0
125 x 85 x 68
G 1'' external
44 x 44
186
400 / 25
16 / 10
2,27
19,5
4,1 / 0,8
4,2 / 0,8
3
Automatic
Reverse cycle
Yes (heated)
Yes
1
Internal
5,0
2,33