TABLE "A" - PARAMETERS MENU - (PARA )
Parameter
min.
max.
0
120
TCA
TRF. L GHT.
1
180
CLR. T
OP. D IST.
1(***)
50
SLOUD
CL. D IST.
1(***)
50
SLOUD
PARTIAL
10
99
OPENING
1
99
OP. F ORCE
1
99
CLS. F ORCE
1
99
OP. S LWD. F ORCE
CLS. S LWD.
1
99
FORCE
15
99
OP SPEED
15
99
CL SPEED
SLOW SPEED
15
30
0
250
Maintenance
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
(**) Impact forces can be reduced by using deformable edges.
(***) If the calculated value is less than 30 cm, it is set to 30 cm.
28 -
ARES VELOCE SMART BT A500
INSTALLATION MANUAL
Default
Personal
Definition
Automatic clos-
10
ing time [s]
Time-to-clear
traffic light zone
40
[s]
Slow-down
distance during
10
opening [%]
Slow-down
distance during
10
closing [%]
Partial opening
20
[%]
Leaf force
during opening
50
[%]
Leaf force
during closing
50
[%]
Leaf/leaves
force during
50
opening during
slow-down
Leaf/leaves force
during closing
50
during slow-down
[%]
Opening speed
99
[%}
Closing speed
99
[%]
Slow-down
25
speed [%]
Programming num-
ber of operations
0
for maintenance
threshold
[in hundreds]
Waiting time before automatic closing.
Time-to-clear for the zone run through by traffic controlled by the traffic light.
Slow-down distance for motor(s) during opening, given as a percentage of total
travel. WARNING: Once the parameter has been edited, a complete uninterrupted
opening-closing cycle is required.
WARNING: when the display reads "SET", obstacle detection is not active.
Slow-down distance for motor(s) during closing, given as a percentage of total travel.
WARNING: Once the parameter has been edited, a complete uninterrupted
opening-closing cycle is required.
WARNING: when the display reads "SET", obstacle detection is not active.
Partial opening distance as a percentage of total opening following activation of PED pedestrian
command.
Force exerted by leaf/leaves during opening. This is the percentage of force delivered,
beyond the force stored during the autoset cycle (and subsequently updated), before
an obstacle alarm is generated.
The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that current safety
requirements are met with the set value (*). Install anti-crush safety
devices where necessary (**).
Force exerted by leaf/leaves during closing. This is the percentage of force delivered,
beyond the force stored during the autoset cycle (and subsequently updated), before
an obstacle alarm is generated.
The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that current safety
requirements are met with the set value (*). Install anti-crush safety
devices where necessary (**).
"Force exerted by leaf/leaves during opening at slow-down speed. "
This is the percentage of force delivered, beyond the force stored during the autoset cycle (and
subsequently updated), before an obstacle alarm is generated.
The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that current safety
requirements are met with the set value (*). Install anti-crush safety
devices where necessary (**).
"Force exerted by leaf/leaves during closing at slow-down speed. "
This is the percentage of force delivered, beyond the force stored during the autoset cycle (and
subsequently updated), before an obstacle alarm is generated.
The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that current safety
requirements are met with the set value (*). Install anti-crush safety
devices where necessary (**).
Percentage of maximum speed that can be reached by motor(s) during opening.
WARNING: Once the parameter has been edited, a complete uninterrupted
opening-closing cycle is required. WARNING: when the display reads "SET",
obstacle detection is not active.
Percentage of maximum speed that can be reached by motor(s) during closing.
WARNING: Once the parameter has been edited, a complete uninterrupted
opening-closing cycle is required. WARNING: when the display reads "SET",
obstacle detection is not active.
Opening and closing speed of motor(s) during slow-down stage, given as a percentage of
maximum running speed. WARNING: Once the parameter has been edited, a complete
uninterrupted opening-closing cycle is required. WARNING: When the display reads
""SET"", obstacle detection is not active.
Allows you to set a number of operations after which the need for maintenance will be repor-
ted on the AUX output configured as Maintenance or Flashing Light and Maintenance .
Description