Troubleshooting
Condition
Motor fails to run.
PowerLuber fails to dispense grease.
PowerLuber continues to lose prime.
Battery fails to take a charge.
Possible cause
Battery needs charging.
Faulty wiring to motor.
Grease tube assembly is out of grease.
Loss of prime.
Ball check (14) is not functioning.
Air may be trapped in several locations in container
after bulk filling.
Follower may be binding in grease tube assembly.
Check ball seat and check ball dirty.
Charger may not have power.
Battery may be bad.
15
Corrective action
Recharge battery.
Remove battery, disassemble handle and check
wiring for loose connection.
Check that grease tube assembly has grease.
Repeat priming operation.
Remove ball check (14), clean and inspect ball
seat area.
Empty grease tube assembly, refill and repeat
priming instructions.
Replace grease tube assembly (5). Disassemble
grease tube assembly and clean. Be sure that
follower has properly entered the grease
cartridge.
or
Verify that the follower is not caught on the rim
of the grease cartridge.
Clean check ball and check ball seat.
Check that receptacle has power.
Replace battery.