GYS Ergo Lift 650 Manuel D'utilisation Et De Maintenance page 36

Élévateur
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

 
CHECK POINT AND LUBRICATION
-
All joints are provided with small holes for lubrication with SAE 90 type oil (fluid oil). The 20 lubrication
points are listed below (1). One drop per hole is enough!
-
Check the tightness of the individual screws at the joints. The lock washer must always remain flat
(2).
-
Check the presence of the stops on the 4 pads that prevent the pad from being completely unscrewed
from its support (3).
 
 
 
 
 
 
 
X 4 
(3) 
 
 
 
 
-
Test each of the 4 arms and check that they can move over their full range of motion. The arm must
not be able to exceed a maximum angle of 135°. If this is not the case, the presence of the stop must
be checked. At the same time, check that the arms engage in the locking catches. Otherwise, unscrew
the screws of the toothed plate without forcing (the indexing plate may have moved sideways, pre
unscrew each screw slightly, then all the screws so as not to damage the threads of the screws and
the lift). Reposition the plate so that the notches can pass through and tighten each of the screws to
12N.m. In the event of a problem, contact Customer Service or your dealer to carry out a complete
replacement of the indexing system (refer to the exploded view on page 41, replace the screws and
lock washers at the same time).
 
 
 
max. stop 
 
 
 
135° maxi 
 
(2) 
(1) 
X 2 
(1) 
X 8 
(2) 
0°  
ERGO LIFT 650
(2) 
(1) 
X 8 
(1) 
X 2 
(2) 
 
35 