A3 00
Reclosing after blackout
00
OFF (does not reclose when the power is restored)
01
ON (recloses when the power is restored)
NOTE: parameter
If this parameter is set to
5 s (even if not enabled on parameter
during the reclosing because it guarantees that the gate is closed when the supply voltage is restored.
After the blackout the position of the wing is unknown, and if the phase shift in closure is enabled,
reclosing takes place one wing at a time in "position recovery" mode.
After the blackout the position of the door is not known and the re-closing takes place in "position
recovery" mode.
A4 00
STEP-BY-STEP MODE (PP)
00
OPENS - STOPS - CLOSES - STOPS - OPENS
01
PP CONDOMINIUM, command PP refreshes the rest time from fully opened
02
PP CONDOMINIALE, command PP closes from fully opened
03
OPENS – CLOSES – OPENS - CLOSES
04
OPENS – CLOSES – STOPS – OPENS
NOTE: parameter
Condominium means that the command PP is ignored when opening.
In installations where multiple users may arrive at the same time, and therefore trigger the radio
control while the gate is operating, is useful to ensure the completion of the opening: it is possible to
prevent two activations by different users from reversing the motion by closing the gate.
By setting the parameter to the value
command does not perform a closure but restarts the count of the rest time.
A5 00
Pre-flashing
00
OFF (the flashing light is only on when there is movement)
01
10
DURATION IN SECONDS of the early activation of the flashing
-
99
not performed when opening; 5 seconds of pre-flashing when closing
NOTE: parameter 5- in simplified mode
A6 00
Condominium function with PEDESTRIAN (PED)
00
OFF (pedestrian control performs AP-ST-CH-ST-AP- ...)
01
ON (pedestrian control operated when opening is ignored)
A7 00
Man present
00
OFF (the controls work normally)
01
ON (the gate only moves by holding down AP or CH)
The motors will only remain active in the presence of a continued command; only the commands AP
and CH are enabled; the motor will stop upon release of the command.
The commands must be positioned so as to be able to check the movement of the gate.
32
3-
in simplified mode.
01
lthe control unit, when on, performs the reclosing after a pre-flashing lasting
A5
6-
in simplified mode
). This feature is useful when there is no longer the supply voltage
01
, if the gate is open, the activation of the step-by-step