the control unit automatically enters position
recovery mode (this does not happen if the door
is located on one of the two limit switches).
RECEIVER CARD, connector for plug-in radio
receiver (see Figure 3).
If you need to access the encoder, the limit switch
or microswitch of the motor release, remove the
support of the electronics, as shown in Figure 10.
4.1
Standard photocells configuration
Inputs FT1 and FT2 are enabled as a production
standard.
Below is the standard configuration of the photo-
cells and related parameters of the extended mode:
FT1 ignored during opening
FT1 interruption during closure causes
a reversal of motion, i.e. it opens
allows for the activation of the motors
to opening even if FT1 is obscured
FT2 interruption during opening
causes a stop; once the beam is
released it continues to open
FT2 interruption during closing
causes a stop; once released the
beam is reversed, i.e. it opens
allows for the activation of the motors
opening even if FT2 is obscured
IF THE PHOTOCELLS ARE NOT INSTALLED
50 00
51 00
Set
,
54 00
Or electrically bridge their terminals with the COM
terminal block.
4.2
Standard safety edges configuration
Inputs COS1 e COS2 are enabled as a production
standard.
Below is the standard configuration of the safety
edges and related parameters of the extended mode:
Intervention safety edge 1 (type
with switch) always reverses the
movement
Intervention safety edge 2 (type
with switch) only reverses the
movement when closing
50 00
51 02
52 01
53 03
54 04
55 01
53 00
,
and
73 03
74 01
IF THE SAFETY EDGE ARE NOT INSTALLED
73 00
74 00
Set
and
Or electrically bridge their terminals with the COM
terminal block
4.3
Connection of the motor and the
encoder
.
The motor is connected in the factory.
CAUTION! If for any reason the wires of the motor
become disconnected from its terminal, you must
carry out a programming of the stroke (because
with this the operation of motor timing is also
performed).
CAUTION! Disconnect and reconnect the cable
connecting to the encoders only with the control unit
de-energized: otherwise if there is a malfunction of
the motor, with the possibility of activations that
are out of control.
4.4
Radio receiver coupling
The receiver (see figure 3) provides two functions
for radio remote control that are assigned in the
following way as a production standard:
PR1 step-by-step control (can be changed by
adjusting parameter
PR2 command
pedestrianopeningcontrol
be changed by adjusting parameter
extended mode)
The 2 programming buttons are accessible with the
electronics cover closed. (see Figure 9).
5
Display operation modes
The screen can display the following information,
depending on the operating mode the control unit
is in:
• COMMANDS AND SAFETY PROTECTIONS STATUS
MODE: the status of the control inputs is shown
by two digits on the left, in the two digits on the
right the status of the safety protections is shown
by two digits on the right
• PARAMETERS MODE: the two digits on the left
will display the name of the parameter, the two
digits on the right display its numerical value
In the simplified mode, standard production, for
example:
In extended mode, to be activated intentionally,
for example:
NOTE: in extended mode the parameter name is
highlighted by the presence of two illuminated
.
76
of extended mode)
77
(can
of
25