Télécharger Imprimer la page

Roger Technology B70/1DC Instructions Et Avertissements Pour L'installateur page 23

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 63
TABLE OF CONTENTS
1 Introduction to the instructions and warnings 23
2 Technical product characteristics B70/1DC 23
3 Product description
4 Description of connections and fuses
4.1 Standard photocells configuration
4.2 Standard safety edges configuration
4.3 Connection of the motor and the encoder 25
4.4 Radio receiver coupling
5 Display operation modes
5.1 Commands and safety protections status
mode
5.2 Parameters mode
5.2.1 Changing a parameter
5.2.2 Restoring standard factory parameters 26
5.2.3 Simplified/extended parameters mode
change
5.3 Standby mode
5.4 TEST mode
6 Installation
6.1 Stroke programming sequence
7 PHOTOCELL TEST mode
8 Error reporting
9 Actuating mechanical release system
10 Position recovery mode
11 Battery operation mode
12 Extended operation mode
13 Inspection
14 Maintenance
15 Disposal
16 Pictures and schemes
2
Technical product characteristics B70/1DC
SUPPLY VOLTAGE
MAXIMUM POWER CONSUMPTION
CONNECTIBLE MOTORS
POWER SUPPLY MOTOR
MOTOR TYPES
MOTOR CONTROL TYPE
RATED POWER MOTOR
MAXIMUM POWER MOTOR
MAXIMUM POWER FLASHING
INTERMITTENT FLASHING
MAXIMUM POWER COURTESY LIGHT
GATE OPEN LIGHT POWER
ACCESSORIES OUTPUT POWER
OPERATING TEMPERATURE
PRODUCT DIMENSIONS
pag.
1
Introduction to the instructions and warnings
This manual is only intended for personnel
24
qualified to perform the installation.
24
No information contained in this document may be
25
considered of interest to the end user.
25
This manual refers to control panel B70/1DC
for sliding gates automations installed with ROGER
25
brushless motors and should not be used for other
25
purpose.
26
26
26
WARNINGS
27
To avoid the risk of electrocution and physical injury
28
always cut the power before intervening on the
28
device.The installation must only be carried out by
28
qualified service personnel according to applicable
29
regulations.Make the connections to the currents
29
and voltages required with the appropriate cables;
29
observe the product's technical characteristics.
30
Check the conformity of the earth system and the
30
continuity between the earth on the motor side and
30
the control unit's terminal block.
31
39
39
39
121
230Vac ± 10% 50Hz
200W
1
24Vac with self-protected invert
brushless sinusoidal (ROGER BRUSHLESS)
Field oriented control (FOC), sensored
60W
150W
25W (24Vdc)
50%
100W 230Vac - 40W 24Vac/dc (pure contact)
3W (24Vdc)
10W (24Vdc)
-20°C ... +55°C
Dimension in mm. 200x90x45 Weight: 0.244Kg
Read the
instructions
carefully before
starting the
installation.
ELECTROCUTION
HAZARD
EN
23

Publicité

loading