Télécharger Imprimer la page

B.S. Service PCI 29 TC 2K Notice D'utilisation page 32

Table vetroceramique

Publicité

Les langues disponibles
  • FR

Les langues disponibles

as a guide for installation, adjustment and maintenance in
conformity with the laws and regulations in force.
Positioning (Fig.6):
The appliance is made for fixing into a worktop, as shown in
the relevant figure. Apply the supplied sealant to the entire
perimeter of the hob and insert it into the fitment hole (for
sizing see Fig.6B). Fix the appliance into the worktop with the
4 stays, rotating them according to the top's depth (Fig.6A).
If the underside of the appliance will be accessible after
installation, a separator panel G (Fig.9A) will need to be
mounted maintaining the distances shown (Fig.9B).
If the appliance is installed over an oven the panel is not
necessary (Fig.10A-10B).
Important: if there is an oven under the induction hob it is
advisable for it to have a cooling fan. Do not use the induction
hob while PYROLITIC cleaning is in process.
Warning: to allow the circulation of as much fresh air as
necessary, there must be at least 40 mm between the
induction hob module and any appliance installed under it
(Fig.10B). In any event, adequate aeration must be provided.
To allow fresh air circulation there must be openings in
the kitchen furniture (Fig.9A-10A) of the sizes indicated in
Fig.9B-10B.
Electrical connections (Fig.4):
Before making the electrical connections, check that:
- the ground cable is 2 cm longer than the other cables;
- the system ratings meet the ratings indicated on the identi-
fication plate fixed on the lower part of the worktop;
- the system is fitted with efficient earthing compliant to the
laws and regulations in force.
If the appliance is not fitted with a cable, use type:
"H05V2V2-F" for a power level of up to 6400 Watts. The cross-
section of the cable should be at least 2.5 mm², or 4 mm² for
greater power levels. The cable should never reach a tem-
perature which is 50°C above the temperature of the room in
which it is installed. The appliance is designed for permanent
connection to the electricity supply and should therefore be
fitted with an omnipolar switch which has a minimum opening
of 3 mm between contacts. The switch should be suitable for
the charge indicated on the appliance data plate and must
conform to all current legislation (the yellow/green earth wire
must not be interrupted by the switch).
The omnipolar switch must be easy to reach once the instal-
lation process has been completed.
USE AND MAINTENANCE
• Use (Fig.3):
A = ON/OFF key
B = Cooking zone display
C = Cooking zone selection key
D = "-" key / Timer "-" key
E = "+" key / Timer "+" key
F = Timer Display
I = Decimal point indicator
- To activate the hob, press the "ON/OFF" key. Some zeros with
flashing decimal points will appear for about 20 seconds on
all the displays.
If no operation is carried out within this time, the hob will
turn off.
- A cooking zone may be switched on by selecting one of
the "C" keys.
- The display will view the corresponding numbers; the grading
of the concerned zone will be intense while the others will be
weaker.
- Use "+" or "-" buttons to regulate the power level.
- By selecting the "-" key the power level goes directly to 9.
- If after about 10 seconds no operation is carried out, display
shade goes back to the initial one. The hob will continue its
normal cooking.
- If the power level is set at zero, the cooking zone will shut
off.
- To turn off the cooking zone, select the corresponding "C"
key and switch the cooking level to 0.
- The display will view the corresponding numbers; the grading
of the concerned zone will be intense while the others will be
weaker.
- All operations will be combined with a "BEEP" acoustic
signal.
- When a cooking zone "C" is brought to the OFF position and
the glass top temperature is greater than approximately 50°,
the display of the interested zone will signal a fixed "H".
Warning:
To prevent damage being inflicted on the electronic circuits,
the hob is fitted with an overheating safety system.In
situations where the appliance is used at high power levels for
a prolonged period of time, the hob may switchoff one or more
of the activated zones temporarily, until the temperatures
return to the set levels.On the display corresponding to the
cooking zone which has been temporarily switched off, the
power level will be shown in alternation with a E/2.This will
stop flashing once the cooking zone has beenreactivated.
• Key function:
To keep children or persons needing supervision from using
the hob surface, all of the functions can be blocked in the
following way:
1- Switch to hob on (if it is off ) by selecting the "ON/OFF"
key. The cooking zones must be off.
2- Press the "-" key and the R2 (Fig.2) key simultaneously.
3- Press only the cooking zone R2 (Fig.2) key once again.
The "L" letter indicating that the function is active will appear
on the display.
Should one or more zones still be hot, the letter "H" and "L"
will alternate on the relative displays.
- 31 -

Publicité

loading