Spray downwind and avoid drift
Keep constant height

4.2. Calibration of manual knapsack sprayer

Using calibrator bottle (optional).
• Hold the lance at the working height and spray to measure
the application band width.
• Based on the band width, calculate the total walking distance
required to spray the desired area. Use the chart below.
Band
width
Band width
0.5
0.7
1.0
1.2
(m)
Distance to
50.5
35.7
25.0
20.8
walk (m)
Attach the calibrator bottle to the lance as shown:
Lance
Cover
Filter
Nozzle
Nozzle cap
Calibrator
bottle
6/68
Record the time it takes to
Simulate the spraying of 25 m²
walk 25 m²
1.
Remove the cap, nozzle and filter.
2.
Mount the calibrator cover to the lance.
3.
Reinstall the filter, nozzle and cap.
4.
Screw the calibrator onto the cover.
• Hold the lance at the normal working height and spray into
the bottle while walking the distance required to spray an
area corresponding to 25 m².
• Place the bottle on a level surface and observe the liquid level
visible through the side of the bottle. Match the liquid level to
the corresponding scale on the calibrator bottle.
• Empty the bottle and repeat this operation to determine the
average of two or more readings.
NOTE: For the volume in liters per bushel (L / alk), simply multiply
the value obtained in liters per hectare (L / ha) by 2.42.
1.5
WARNING!
16.7
Wear a protective clothes to do the mainte-
nance and parts replacement.

4.3. Choosing nozzle type

Seven main nozzle designs are used on knapsack sprayers. Each
nozzle design is available in a range of sizes to optimize the use
of product to be applied. The nozzle choice will be based on the
agrochemical type to be used and the droplet size recommend-
ed (table):
NOTE: This sprayer is packaged with Blue Adjustable Cone noz-
zle fitted in the lance. Other nozzles mentioned in this manual
are optional, so they do not accompany this sprayer.
NOZZLE
IDENTIFICATION
PRESSURE
FILTER (Mesh)
APPLICATION
TYPE
(Part no. - Description)
(psi)
(1197535) JEF 110015
80 (Zinc yellow)
30
GREEN
(1197536) JEF 11002
Herbicides
50(Gentian blue)
30
YELLOW
(1197537) JEF11003
50(Gentian blue)
30
BLUE
(1197475) JSF 110015
80 (Zinc yellow)
30
GREEN
(1197476) JSF 11002
50(Gentian blue)
Herbicides
30
YELLOW
(1197477) JSF11003
50(Gentian blue)
30
BLUE
(1197565) JHC 8002
50(Gentian blue)
45
YELLOW
Fungicide,
(1198892) JHC 8004
insecticide
50(Gentian blue)
45
RED
and
foliar
(1198893) JHC 8005
fertilizers
45
50(Gentian blue)
BROWN
(1197486) JDF 04
50(Gentian blue)
15
RED
Herbicides
(1197487) JDF 05
and
50(Gentian blue)
15
BROWN
foliar
fertilizers
(1197488) JDF 06
50(Gentian blue)
15
GREY
(1197497) JAI 120015
80 (Zinc yellow)
20
GREEN
(1197499) JAI 12002
80 (Zinc yellow)
Herbicides
20
YELLOW
(1197501) JAI 12003
50(Gentian blue)
20
BLUE
Nozzle
Herbi-
Fungi-
cide
cide
Code
Name
Picture
1197571
JHC
217174
JD-12
1197537
JEF
1197477
JSF
325787
J ADJ
1197486
JDF
1197486
JAI
Recommended
Acceptable
Not recommended
Prevent the flow rate to be higher than 10% of the nozzle nom-
inal flow rate.
It is recommended to use the pressure and flow rate regulating
valve (ECOVALVE) in order to achieve a more accurate spraying
method.
FLOW RATE
(l/min)
0.49
Code:1197164
0.65
0.98
0.49
Code:1197159
0.65
0.58
0.80
Code:1197163
1.60
2.00
0.92
Code:1197162
1.15
1.39
0.42
0.57
0.85
Insec-
ticide
0.8 Bar (0.8 kgf/cm²)
1.0 Bar (1.0 kgf/cm²)
1.2 Bar (1.2 kgf/cm²)
1.3 Bar (1.3 kgf/cm²)
1.5 Bar (1.5 kgf/cm²)
1.7 Bar (1.7 kgf/cm²)
1.8 Bar (1.8 kgf/cm²)
2.0 Bar (2.0 kgf/cm²)
2.3 Bar (2.3 kgf/cm²)
2.8 Bar (2.8 kgf/cm²)
3.0 Bar (3.0 kgf/cm²)
3.2 Bar (3.2 kgf/cm²)
7/68