EduTrainer 24 V power supply unit

11 Technical data

General information
Device operation
Dimensions (H x W x D in mm)
Weight
Electrical components
Input voltage
Input frequency
Input current
Protection class
Overvoltage category
Pollution degree
Degree of efficiency
Mains connection
Output voltage
Output voltage ripple
Output current
Short-circuit protection
Overload protection
Operating temperature range
Max. relative humidity
Degree of protection
Approvals
CE marking
38
Use only indoors, up to 2000 m above sea level
297 x 133 x 140
Approx. 1 kg
110...240 V AC (±10 %)
50...60 Hz
1.0 A (110 V AC)
0.52 A (240 V AC)
1, operation with protective grounding
II, operation in building installations
2. Laboratory environment
80 %
4 mm safety sockets
24 V DC, 1%
150 mV
4 A
Switching off the switched-mode power supply unit
Resettable device fuse (4 A)
5...40°C/100%
80 %
IP 20 (not attached to the ER mounting frame)
To Low Voltage Directive,
EMC Directive (EN 55011 class B)
RoHS Directive
© Festo Didactic 8049693