SYSTEM LAY-OUT
710/28
40/
1,56
630/24,8
Measurements in mm/inch
Barrier INDUSTRIAL
- Photoelectric cells
- Galvanized column for P.E. cells
- Strip with Photo electric cells
- Magnetic loop
- Key selector
- Tuned aerial
T
ECHNICAL FEATURES
Irreversible actuator to operate barriers ranging from 7.5 m to 12 m in length.
The barrier can be supplied with a galvanized and painted or stainless steel casing.
The boom arm can be supplied with a hanging rack up to a maximum length of 8.5
m (Pic. 1).
N.B. You must make installation features comply with laws and standards in force.
Parts to install meeting the EN 12453 standard
COMMAND TYPE
with manned operation
with visible impulses (e.g. sensor)
with not visible impulses
(e.g. remote control device)
automatic
* a typical example are those shutters which do not have access to any public way.
A: C ommand button with manned operation (that is, operating as long as activated), like code ACG2020.
B: Key selector with manned operation, like code ACG1010.
C: S afety edges, like code ACG3010 and/or other safety devices to keep thrust force within the limits
of EN12453 regulation - Appendix A.
D: Photocells, like code ACG8026.
L = 12/0,47 max
40/1,56
USE OF THE SHUTTER
Skilled persons
Skilled persons Unrestricted
(out of a public area*)
(public area)
A
B
C
C
C
C e D
C e D
C e D
=
TECHNICAL
DATA
Max. boom lenght
Opening time
Max. torque
Power supply
Motor capacity
Power absorbed
Normative cycles
Power supply
Motor capacity
Power absorbed
Normative cycles
Power supply
Motor capacity
Power absorbed
Normative cycles
Power supply
Motor capacity
Power absorbed
Normative cycles
use
Daily operations suggested
C e D
Service
C e D
Consecutive cycles guaranteed
C e D
Lubrification
Actuator weight
Noise
Volume
Operating temperature
Protection grade
25
25
=
BA10003
Fix the SHOCK-ABSORBER
in the MIDDLE of the boom arm.
In case of installation with the
HANGING RACK, please see
pict. 8 and 9.
INDUSTRIAL
m
s
Nm
400V~ 50/60Hz
W
A
n°
50 - 16s/2s
230V~ 50Hz
W
A
n°
40 - 16s/2s
380V~ 60Hz
W
A
n°
150 - 16s/2s
220V~ 60Hz
W
A
n°
100 - 16s/2s
n°
100%
n°
SHELL OMALA 100
kg
db
m
0,441
3
°C
-10 ÷ +55
IP
G
B
1
12
16
800
800
1,2
660
1,7
760
1,1
745
1,9
300
300
210
<70