RITE-HITE
®
Manuel d'utilisation du niveleur de quai RHH50
SCHÉMA ÉLECTRIQUE (SUITE)
DEPUIS ALIMENTATION ET DISPOSITIF DE PROTECTION DE SURETE DU CLIENT
208-240V, TRIPHASE, 60Hz, UTILISER FUSIBLES DOUBLES TEMPORISES 6.0A
380-415V, TRIPHASE, 50/60Hz, UTILISER FUSIBLES DOUBLES TEMPORISES 4.0A
440-480V, TRIPHASE, 60Hz, UTILISER FUSIBLES DOUBLES TEMPORISES 4.0A
100
575V, TRIPHASE, 60Hz, UTILISER FUSIBLES DOUBLES TEMPORISES 4.0A
101
1FU1
L1
102
1FU2
L2
1FU3
L3
103
G
104
SECTIONNEUR A FUSIBLE
(DE TIERS)
VOIR NOTE 9
105
106
TRANSFORMATEUR POUR COMMANDES DE NIVELEUR
HYDRAULIQUE SEULEMENT! NE PAS UTILISER POUR
107
ALIMENTER DES EQUIPEMENTS AUXILIAIRES.
108
H2(RD)
109
'ARRET D'URGENCE'
H2(RD)
110
PB3
CR1-1
111
H3(RD)
(14)
112
H3(RD)
113
114
H5(RD)
115
116
H3(RD)
117
118
PB1
119
VERS BOITIER DE COMMANDE
DOK-LOK POUR INTERCONNEXION
DE DISPOSITIF DE RETENUE
120
H3(RD)
121
LE BLOC DE CONTACT EST N.O. LORSQUE
L'ARRET D'URGENCE N'EST PAS NECESSAIRE
H3
122
H3(RD)
(BORNE SUSPENDUE DE MAINTENANCE)
18
VOIR NOTE 3
1L1
1L1
1L2
1L2
1L3
1L3
FIL EN CUIVRE
N°16GA MINIMUM
90°C, NOIR
2FU1
2L1
(H3)
(H1)
ATTENTION
10FU1
(X1)
'MONTEE'
H2A(RD)
H2B(RD)
H2A(RD)
(11)
H5
H5(RD)
'VERROUILLAGE DE PORTE'
H5B(RD)
'LEVRE SORTIE'
H4A(RD)
H4(RD)
'INTERRUPTEUR DE FIN
DE COURSE ARTD'
H4
4(BLK)
7 (BLK)
H7
H7(RD)
PB2
1. CONFIER TOUTE L'INSTALLATION ET LA MAINTENANCE A DU PERSONNEL QUALIFIE.
2. CABLAGE EXTERIEUR D'ALIMENTATION D'ENTREE – VOIR TABLEAU DES TAILLES DE
CABLE MINIMUM.
3. ALIMENTATION DEPUIS SECTIONNEUR POUR COMMANDER LE BOITIER ET LE
MOTEUR DU NIVELEUR LE CABLAGE EXTERIEUR DOIT ETRE UN FIL EN CUIVRE
N°14GA MINIMUM, 60°/75°C SUFFISAMMENT ISOLE POUR LA TENSION D'ENTREE.
4.TOUT CABLAGE EXTERIEUR DE COMMANDE DOIT ETRE UNIQUEMENT UN FIL EN
CUIVRE N°14GA MINIMUM, 60°/75°C, SUFFISAMMENT ISOLE POUR LA TENSION D'ENTREE.
5. TOUT LE CABLAGE INTERIEUR DU BOITIER DE COMMANDE DOIT ETRE UN FIL EN
CUIVRE ROUGE N° 18GA MINIMUM, 90°C SAUF INDICATION CONTRAIRE, SUFFISAMMENT
ISOLE POUR LA TENSION D'ENTREE.
6. COUPLES DE SERRAGE:
CONTACTEUR 8.9-22 LB-IN (MINI.-MAXI)
RELAIS DE SURCHARGE: 16 LB-IN
BORNE DE TERRE: 36 LB-IN
BORNIER: 5.0-5.6 LB-IN (MINI.-MAXI)
FIGURE 16 - SCHÉMA ÉLECTRIQUE - TRIPHASÉ
UN NIVELEUR PAR DISPOSITIF DE PROTECTION
CONTRE LES SURCHARGES
(REF. DERNIERE EDITION DE
NEC SECTION 430)
1MCR
1OL
FUSIBLE PRIMAIRE DE TRANSFORMATEUR
CLASSE CC, DOUBLE TEMPORISE
208-240V, UTILISER 1.0 A, 600 V
2FU2
380-480V, UTILISER 0.5 A, 600 V
575 V, UTILISER 0.4 A, 600V
2L2
(H2)
(H4)
50VA
0,5A, 250V
FUSIBLE DOUBLE TEMPORISE
N°12GA MINIMUM,
(X2)
VERT
120v.
RELAIS D'INTERFACE ESB
(A1)
CR1-2
H2B(RD)
(11)
(14)
(A1)
BORNIER
CAVALIER
H5A
H5A(RD)
LS2
(4)
(3)
G
ILLUSTRE AVEC
N.O.
PORTE FERMEE
3
~
(-)
LS1
R
12(WHT)
H12
G
N.O.
SOLENOIDE 1
LEVRE SORTIE
X2 (WHT)
X2/N
120Vca, 0,3 A
MOTEUR DE NIVELEUR, 1 HP
(VOIR TABLEAU D'INTENSITE
MAXI. MOTEUR)
A 3450 TR/MIN.
240V, TRIPHASE, 60Hz
T1
T2
T3
1
2
3
7
8
9
VOIR NOTE 3
4
5
6
T1
BRANCHER T1, T2, T3
AUX BORNES 1, 2, 3
T2
SI LA ROTATION EST
M
INCORRECTE, INVERSER 2
DES LIGNES
T3
G
MOTEUR DE NIVELEUR, 1 HP
(VOIR TABLEAU D'INTENSITE
MAXI. MOTEUR)
A 3450 TR/MIN.
480V, TRIPHASE, 60Hz
T1
T2
T3
1
2
3
7
8
9
4
5
6
BRANCHER T1, T2, T3
AUX BORNES 1, 2, 3
SI LA ROTATION EST
INCORRECTE, INVERSER 2
DES LIGNES
X2(WH)
CR1-1
CIRCUIT D'ARRET
X2(WH)
D'URGENCE
(A2)
120VAC
CR1-2
X2(WH)
(A2)
120VAC
COMMANDES
X2(WH)
NIVELEUR
H5B(RD)
X2(WH)
TMR1:
IMPULSION
2
1
L
ARTD
~
V
(+)
S1
CIRCUIT
4
6
5
T
CIRCUIT
X2(WH)
SORTIE
LEVRE
7. LS1 FOURNI PAR RITE-HITE AVEC NIVELEUR POUR ARTD.
LS2 FOURNI PAR RITE-HITE OU DES TIERS POUR PORTE BASCULANTE.
8. VOIR MANUEL D'UTILISATION POUR DES INSTRUCTIONS COMPLETES.
9. NOTES SUR LE SECTIONNEUR A FUSIBLE:
- LE SECTIONNEUR A FUSIBLE N'EST PAS FOURNI PAR RITE-HITE PRODUCTS
CORPORATION. IL DOIT ETRE FOURNI PAR DES TIERS ET INSTALLE SELON LA
DERNIERE EDITION DES REGLEMENTS UL508A ET NEC.
- UN SECTIONNEUR DE CIRCUIT DE DERIVATION DOIT ETRE INSTALLE DANS UN
RAYON DE 50 PIEDS ET ETRE VISIBLE DEPUIS L'EMPLACEMENT DU BOITIER DE
COMMANDE.
(REF. DERNIERE EDITION DE NEC, SECTION 430)
10.
LEGENDE:
INDIQUE RACCORDEMENTS DE CABLE A TRAVERS LE BORNIER
INDIQUE CABLES EXTERIEURS
INDIQUE RACCORDEMENT PAR CONNECTEUR DE FIL
INDIQUE RACCORDEMENT PAR PRISE MALE/FEMELLE
Pub. n° 1336 - Juillet 2012
MOTEUR DE NIVELEUR, 1 HP
(VOIR TABLEAU D'INTENSITE
MAXI. MOTEUR)
A 3450 TR/MIN.
380V, TRIPHASE, 50/60Hz
T1
T2
T3
1
2
3
7
8
9
4
5
6
BRANCHER T1, T2, T3
AUX BORNES 1, 2, 3
SI LA ROTATION EST
INCORRECTE, INVERSER 2
DES LIGNES
MOTEUR DE NIVELEUR, 1 HP
(VOIR TABLEAU D'INTENSITE
MAXI. MOTEUR)
A 3450 TR/MIN.
575V, TRIPHASE, 60Hz
T1
T2
T3
1
2
3
BRANCHER T1, T2, T3
AUX BORNES 1, 2, 3
SI LA ROTATION EST
INCORRECTE, INVERSER 2
DES LIGNES