WARNING for Using R32/R290 Refrigerant
● When flammable refrigerant are employed, appliance shall be stored in a well -ventilated area where
the room size corresponds to the room area as specifiec for operation.
For R32 frigerant models:
Appliance shall be installed, operated and stored in a room with a floor area larger than X m
Appliance shall not be installed in an unvertilated space, if that space is smaller than X m
(Please see the following form).
Model (Btu/h)
Amount of refrigerant to be charged (kg)
≤12000
18000
24000
30000
36000
42000-48000
60000
● Reusable mechanical connectors and flared joints are not allowed indoors.
(EN Standard Requirements).
● Mechanical connectors used indoors shall have a rate of not more than 3g/year at 25% of the
maximum allowable pressure. When mechanical connectors are reused indoors, sealing parts shall
be renewed. When flared joints are reused indoors, the flare part shall be re-fabricated.
(UL Standard Requirements)
● When mechanical connectors are reused indoors, sealing parts shall be renewed. When flared joints
are reused indoors, the flare part shall be re-fabricated. (IEC Standard Requirements)
● Mechanical connectors used indoors shall comply with ISO 14903.
European Disposal Guidelines
This marking shown on the product or its literature, indicates that waste electrical and eletrical
equipment should not be mixed with general household waste.
This appliance contains refrigerant and other potentially hazardous materials. When disposing of
this appliance, the law requires special collection and treatment. Do not dispose of this product as
household waste or unsorted municipal waste.
When disposing of this appliance, you have the following options:
• Dispose of the appliance at designated municipal electronic waste collection facility.
• When buying a new appliance, the retailer will take back the old appliance free of charge.
• The manufacturer will take back the old appliance free of charge.
• Sell the appliance to certified scrap metal dealers.
Special notice
Disposing of this appliance in the forest or other natural surroundings endangers your health and is bad
for the environment. Hazardous substances may leak into the ground water and enter the food chain.
≤1.11
≤1.65
≤2.58
≤3.08
≤3.84
≤4.24
≤4.39
(Waste Electrical & Electronic Equipment)
Installation height
Minimum room area (m²)
2.2m
2.2m
2.2m
2.2m
2.2m
2.2m
2.2m
Correct Disposal of This Product
2
.
2
.
1
2
5
7
10
12
13
Page 7-GB