4.12- Hydraulic unit
If there is not a pressure limiter on the hydraulic power unit, you need to install one set with a
max pressure of 140 bars. It will guaranty to avoid too much pressure in the motorized unit.
If the flow of the hydraulic unit is not clearly specified, you already need to install a flow
limiter. That flow limiter has to prevent a flow above 20L/mn. The recommended continuous
flow is 16L/mn.
The motorised unit is normally irreversible. The supply circuit doesn't need to be locked when
the furler is not in rotation.
In order to put the safety square of the handle for example, you need to have a "by-pass"
valve between the two flexibles, or the distributor of the hydraulic unit which control your
furler has to be "open-centre" type.
Models
Max pressure
delivred by the
hydraulic power-
unit
HF700
140 bars
5- STEPS TO ACCESS TO THE TURNBUCKLE
As shown against follow the
steps to have access to the
turnbuckle.
Follow the right order.
Swage the 5 pins of the remote plug.
Enrouleurs hydrauliques FACNOR
Max torque
Maximum
of motorized
revolution
unit
speed (rpm)
15L/mn
400N.m
60 rpm
2
1
code /part No document: 29160050159 –
-
Flow rate of
Power of
hydraulic
motorized unit
power-unit
16L/mn
20L/mn max
2.3kW
intermittent
1
rev 2018
-
page 24/25