LED (moist ground) or of a maximum 2 LEDs (dry ground) (Fig. 2 LED 9 and
8). If this is not the case, then raise the number and / or length of the earth-
ing posts.
4. Energizer Operating Description
Rechargeable battery indicator:
The rechargeable battery indicator (Fig. 2 LED 2) provides information about the rechargeable battery or battery voltage. The
solar display lights up constantly in green when the solar panel charging voltage is greater than the voltage of the rechargea-
ble battery/battery. Whilst the solar panel charges the 12V rechargeable battery, it does not charge the 9 volt battery.
Power economiser:
A fitted power economiser matches power consumption to the state of the fence. This means less current consumption with
well insulated fences and a greater current consumption with poorly insulated fences (leakages due to plant growth, etc.).
5. Maintenance
Table 13 (12V rechargeable battery)
Remaining capacity
Flashing light
green
Flashing light
red/green
20-40%
Flashing light
red
0-20%
The rechargeable battery must be recharged at the latest when discharged down to 20% (only 80% charge capacity left) to
prevent a flat battery. The rechargeable battery indicator (LED2) lights up:
Do note that temperature and measurement deviation may cause these figures to vary.
Caution!
When using a solar system
Only carry out a battery or rechargeable battery test at start of the day ( no solar power supplied - cover panel )
6. Disassembly, Dismantling, Storage and Transport
Disassembly, Dismantling
Before starting disassembly:
● Switch off energizer
● Disconnect entire energy supply from the energizer.
● Remove operating/auxiliary materials and any remaining working materials and dispose of in an environmentally-compati-
ble manner.
Then properly clean sub-assemblies and parts and disassemble them in taking account of the local industrial safety &
environmental protection provisions in force.
Storage, Transport
Ensure that the energizer is both stored and transported only when switched off.
NOTE!
Ensure that rechargeable batteries are stored in ventilated and dry rooms.
8
Rechargeable battery good
40-100%
Charge the battery
Rechargeable battery absolute-
ly depleted
7. Faults and Repairs
WARNING!
Repairs may only be carried out by qualified persons.
Only the spare parts prescribed by the manufacturer may be used.
Subject to technical alterations!
Table 14
Faults
Display
Rechargeable battery under
LED2 flashes alternately red/green
40% capacity
Rechargeable battery under
LED2 flashes red
20% capacity
Corrective action
Charge the battery
Charge the battery
9