Slide fence to approximate position.
Tighten knob (B).
Rotate knurled knob (C) to achieve fine adjustment.
When setting is reached, tighten fence lock knob (A).
Table tilt:
To tilt the table, loosen the lock handle (D, Fig 15) and rotate
the knob (E).
Adjust according to the scale (G).
The 90° table stop (F) must be pivoted out of the way to tilt
table to the left.
Tighten lock handle (D).
Table 90° stop adjustment:
The 90° table stop (F) must be adjusted, so that the table is
square to the sawblade..
Place a square against the saw blade to inspect (F 16).
Fig 14
Fig 15
Loosen nut (F1, Fig 15) to adjust the stop.
Levelling table insert:
Remove table insert to expose set screws in the table.
Rotate screws as needed until insert sits flush with table
surface.
5.3 Mains connection
Mains connection and any extension cords and plugs used
must comply with the information on the machine licence
plate.
The mains connection must have a 16A surge-proof fuse.
Only use extension cords marked H07RN-F, with wires
2
1,5mm
or more.
Power cords and plugs must be free from defects.
Connections and repairs to the electrical equipment may only
be carried out by qualified electricians.
ATTENTION:
-Check first if the saw blade is tensioned and runs freely and if
all safety devices are fitted before starting the machine.
- If the direction of rotation is not correct, the phase
converter inside the CEE Euro plug must be pushed in and
turned 180°.
(The saw blade must run down to the table)
5.4 Dust connection
Before initial operation, the machine must be connected to a
dust extractor. The suction should switch on automatically
when the bandsaw is switched on.
The flow rate on the suction port must be 20m/sec.
Flexible hoses must be of non-flammable quality, and must be
connected to the machine ground system.
5.5 Starting operation
You can start the machine with the green ON-button . The red
OFF-button on the main switch stops the machine.
Fig 16