Trouble Shooting - Vestfrost VLS174A AC Consignes D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 18

Trouble shooting

Fault
Compressor is not
running
Compressor is running,
and the temperature is
too high
No temperature is
displayed
Possible cause
Be patient, it is most likely that the
compressor will start within a few
minutes.
The ventilation grille is blocked.
The lid is not closed properly.
The temperature in the room in which
the appliance is installed is too high.
The micro processor control unit is
broken
Power not connected
Remedy
If this is not the case, check the fol-
lowing:
- Check that power is connected
- Check the fuse and replace it if
necessary.
- If the above is OK, call technical
supervisor.
Ensure unhindered air circulation.
Ensure that the lid is closed properly.
Shield the appliance against direct
sun light and ensure more ventilation
to the room.
Change the micro processor control
unit.
Check power outlet - Check power
plug is connected.
15
GB

Publicité

Table des Matières
loading

Table des Matières