Télécharger Imprimer la page

Unox ChefTop Gas Notice D'utilisation page 17

Publicité

Les langues disponibles

Les langues disponibles

ENGLISH
10.2 BLAST CHILLER ERROR MESSAGES
BREAKDOWN
The display panel 1 shows the
message EA1
The display panel 1 shows the
message EA2
The display panel 1 shows the
message EA3
Display no. 1 shows continuously
EA4 message
Display no. 1 shows continuously
EA5 message
CAUSE
The connection wires of the cavity
probe are disconnected from the
power card
Damaged chamber probe
Damaged blast chiller power card
The connection wires of the core
probe are disconnected from the
power card
Damaged core probe
Damaged blast chiller power card
Overpressure in the refrigeration
circuit
Damaged blast chiller power card
Filters working limit reached
Oven / blast chiller connecting
cable is damaged or disconnected
Blast chiller power card is
damaged
UNO
SOLUTION
Apply to a UNOX qualified
technician for service
Apply to a UNOX qualified
technician for service
Apply to a UNOX qualified
technician for service
Apply to a UNOX qualified
technician for service
Apply to a UNOX qualified
technician for service
Apply to a UNOX qualified
technician for service
Disconnect the blast chiller from
the power supply, wait for about
20 minutes, and connect again the
appliance: if the display shows
again the message EA3
Apply to a UNOX qualified
technician for service
Apply to a UNOX qualified
technician for service
Take out the filter and wash it
Apply to a UNOX qualified
technician for service
ENGLISH
ENGLISH
R
16
12

Publicité

loading

Ce manuel est également adapté pour:

Bakertop gas