SAFETY
GB
INSTRUCTIONS
Mounting and mainte­
nance are allowed for
qualified
electricians
with
valid
work permit for electric
operations at units up
to 1000  V after careful
study of the user's man­
ual.
· Check the device for any
visible damages of the im-
peller and the casing be-
fore starting installation.
The casing must be free
of any foreign objects
that could damage the
impeller blades.
· This appliance can be
used by children aged
from 8 years and above
and persons with reduced
physical, sensory or men-
tal capabilities or lack of
116
experience and knowl-
edge if they have been
given supervision or in-
struction concerning use
of the appliance in a safe
way and understand the
electrical
hazards involved.
· Children shall not play
with the appliance.
· Cleaning and user mainte-
nance shall not be made
by children without su-
pervision.
· Disconnect
the
from power mains prior
to any connection, servic-
ing and/or repair opera-
tions.
· Misuse of the device or
any unauthorized modifi-
cations are not allowed.
· The device must not be
used to activate water
heaters, room heaters,
etc.
· Do not touch the device
with wet or humid parts
of the body (e.g. hands or
feet).
· The electrical system to
which the device should
be connected must com-
ply with the acting lo-
cal electrical norms and
standards. During instal-
lation, always observe the
national installation regu-
lations.
device
· The device can be con-
nected to the supply
mains only if the voltage
and the frequency of the
supply mains correspond
to those written in the
rating label.
· The fixed electrical wiring
must be equipped with an
automatic circuit breaker
with the gap between the
breaker contacts on all
poles not less than 3 mm
(overvoltage category III
conditions).
· Take steps to prevent in-
gress of smoke, carbon
monoxide and other com-
bustion
products
into
the room through open
chimney flues or other
fire-protection
devices.
Sufficient fresh air sup-
ply must be provided for
proper combustion and
exhaust of gases through
the chimney of fuel burn-
ing equipment to prevent
back drafting. Consult the
local norms with regards
to this.
· It is forbidden for the de-
vice to discharge air into
hot air ducts used for the
evacuation of fumes com-
ing from the combustion
of stoves or other com-
bustion devices.
GB