WIKA Delta-trans Mode D'emploi page 10

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

8. Technical data
Approval German Lloyd (optional)
GB
Additional or deviating technical data
Pressure ranges
Output signal
Permissible ambient
temperature
EMC (electro-magnetic
compatibility)
ESD
Electromagnetic fields
Burst
Conducted HF-disturbance
Surge
Conducted NF-disturbance
Vibration test Fc
2 ... 25 Hz, +/- 1.6 mm
25 ... 100 Hz, 4 g
10
bar
0 ... 0.25 to 0 ... 10
4 ... 20 mA, 2-wire or 0 ... 20 mA, 3-wire current limit I < 32 mA
°C
-10 ... +70
Interference emission per
interference immunity per
kV
± 8
V/m 10
kV
± 2
V
3
kV
± 0.5 symmetrically
kV
± 1
kV
± 1
kV
± 2
Veff
3
%
< 2.5 error
%
< 2.5 error
WIKA Operating Instructions Differential Pressure Transmitter DELTA-trans
EN 50 081-1 (March 93) and
EN 50 081-2 (March 94),
EN 50 082-2 (March 95)
contact discharge
80 % AM, 1 kHz, 0.01 ... 1000 MHz
coupling clamp
80 % AM, 1 kHz, 0.01 ... 100 MHz
asymmetrically, R i = 42 Ohm
symmetrically
asymmetrically, R i = 42 Ohm, with surge
protection only e.g. model MM-DS/x-
NFE(L), firm Dehn & Söhne or equivalent
0.05 ... 10 kHz
IEC 1000-4-2
IEC 1000-4-3
IEC 1000-4-4
IEC 1000-4-6
IEC 1000-4-5
IEC 945
IEC 68-2-6