Installation
To fix the extractor to the kitchen unit the
pattern on page 18 is used.
The lower part of the extractor must be
located at a minimum height of 60 cm
above the hob for electric cookers and 65
cm for gas cookers. If the instructions of
a gas cooker indicate a greater distance
these must be observed.
The extractor must be connected to a
wall socket with an effective earth.
When the extractor is working at the
same time as other non-electrical cook-
ing equipment, the outlet air pressure
must not exceed 4 Pa (4 x 10
-5
bar).
To achieve optimum performance the
length of the outlet hose should not
exceed 4 meters, or include more than
two 90º angles (elbows).
Although venting to the outside is recom-
mended, activated carbon filters may be
used, which allow the gas to be returned to
the kitchen through the outlet pipe.To evacu-
ate via the upper part, an external evacua-
tion conduit is needed and the evacuation
Defect
Possible cause
The extractor
The cable is not connected
does not work
No current is reaching the plug
The extractor does not
Filter saturated with grease
blow enough or vibrates
Outlet obstructed
Inadequate air conduit
The lamps do not light
Lamp broken
Lamp loose
E
I
lever to be located in the "E" position. The
small (anti-return) outlet hose is located,
ensuring that the remaining outlets are duly
plugged. To allow re-circulation through the
active carbon the evacuation lever is located
in the "I" position, ensuring that the upper
opening is plugged. Then the activated car-
bon filter is located in the inlet mouth.
If something does not work
Before seeking technical assistance car-
ry out the following checks first:
Solution
Connect the mains cable
Revise/repair the
electricity circuit
Clean or substitute filter
Eliminate obstructions
Contact the installer and follow
instructions of this manual
Exchange the bulb
Tighten bulb
Special U.K. Requirements
Height above gas hob: 75 mm minimum
NEVER PLACE THE COOKER HOOD OVER
AN EYE-LEVEL GRILL.
This appliance must be connected by a
competent person, using fixed wiring via
a DOUBLE POLE SWITCHED FUSED
SPUR OUTLET.
Electrical connection
We recommend that the appliance is con-
nected by a qualified electrician, who is a
member of the N.I.C.E.I.C. and who will
comply with the I.E.E. and local regulations.
Should the colour of the wires in the mains
lead for the appliance not correspond with
the coloured markings identifying the termi-
nal in your spur box proceed as follows:
TEKA INDUSTRIAL, S.A. reserves the right to make corrections in its appliances wher-
ever it considers these necessary or useful, without harming their essential features.
- The wire which is coloured blur must be
connected to the marked N (Neutral) or
coloured Black.
- The wire which is coloured brown must be
connected to the marked L (Live) or
couloured Red.
- Where avialable (see installation), the wire
which is coloured yellow/green must be
connected to the market
or coloured
Yellow/Green.
If the cooker hood is installed for use above
a gas appliance then the provision for venti-
lation must be in accordance with the Gas
Safety (Installation & Use) Regulations
1984 and the relevant Building Regula-
tions. Detailed recommendations are con-
tained in the following British Standard
Codes of Practice BS6172, BS5440 and
BS6891 Current Edition.