GND (-) = GROUND CONNECTION
Connect the Gnd terminal to the chassis ground of your car and take care
of best electric and mechanic contact. In doing so, drill a hole into the car
chassis near the amplifier, then remove colour, dirt or any other substance
from the ground point. After that, fasten the cable end with added ring
terminal by using a screw. Ensure that the ground connection is as short as
possible and that the cable diameter is sufficient (min. 6mm²). Route the
ground cables from the radio and all other equipment parts, like equalizer,
active crossover network or other amplifiers, to the same ground point.
BATT (+) = POWER SUPPLY
Connect the Batt terminal to the positive pole of the battery with a lead
cable and add a fuse into the power cable in a distance of not more than
30 cm from the battery. The lead cable's diameter should be at least 6mm²
for a length of 3m and 8mm² for a lenght of 6m.
REM (ON / OFF) = REMOTE CONTROL
Connect the Rem terminal to the automatic antenna connector of your car
radio. Now when turning on and off your car radio, the amplifier
automatically switches on and off. A cable diameter of 0.5mm² is sufficient.
ON = LED POWER INDICATOR
After the orderly connection of the three power terminals, the LED indicator
shines green and goes out with "off".
PROTECT = LED PROTECTION INDICATOR
This set is equipped with an overload protection. Immediately upon
overloading (due to short circuit or much increased temperature) the
overload protection is activated, and the LED indicator is shining red.
Through this, the amplifier is protected against damage. In case of thermal
protection a certain short cooling time must be allowed after which the
amplifier automatically resumes operation.