Monosem ECU S6400 Notice D'utilisation page 51

Table des Matières

Publicité

ID
Alarm message
Connection lost.
602
Connection compromised.
603
Supply voltage too low.
604
Short circuit
605
Electrical circuit open load.
606
Error identified in the ERC module
607
No seeding rate detected.
608
Seeding rate detected.
609
Seed flow detected in the disengaged row. The row is faulty.
610
Hopper tank level too low.
611
Hopper empty.
612
Opening time exceeded for a section.
613
Opening time exceeded for a section.
614
Seed flow detected in the inactive row.
617
No product flow detected in the active row. No product flow has been detected in an
618
Excessive product flow detected in the
619
active row.
Insufficient product flow detected in the
620
active row.
There is no record for this product.
621
Charger fault.
622
Connection lost.
630
Undefined module index.
631
Undefined command
632
Motor failure
633
Excessive motor amperage.
634
Excessive actual/set-point rotation speed
635
deviation
No seeds during pre-dosing.
636
Insufficient voltage.
663
Seed monitor error. Error: Sensor:
670
Seed monitor error.
671
SPECIFIC MACHINE ALARMS
Possible cause
The connection with an ERC module has
been lost.
The connection with an ERC module has
been compromised.
The supply voltage for the ERC modules
is too low.
One of the ERC modules has short-
circuited.
An open electrical circuit has been
detected on an ERC module.
The configuration includes errors.
The seed monitor system has detected no
seeding rate.
A seeding rate is detected in a tramline.
There are insufficient seeds or fertiliser in
the hopper.
There are no seeds or fertiliser in the
hopper.
The command for the left section is taking
too long.
The command for the right section is taking
too long.
Product flow has been detected in an
inactive row.
active row.
Excessive product flow has been detected
in an active row.
Insufficient product flow has been detected
in an active row.
A calibration test has not yet been
performed for this product.
The charger generator is faulty.
The connection with an MRC module has
been lost.
A software error has occurred.
A software error has occurred.
The MRC motor has failed.
The MRC motor is using too much power.
The MRC motor's rotation speed has
deviated excessively from the set-point
value.
No seeds were detected during pre-dosing. Ensure that seeds are present.
Voltage is lower than the pre-defined
minimum supply voltage.
An error has occurred in the seed monitor
system.
An error has occurred in the seed monitor
system.
51 51
Solution
Please check the wiring.
Please check the wiring.
Check the supply voltage and check the
machine battery.
Please check the wiring.
Check the wiring and check whether the
disengagement device is in place.
Check the configuration of the inputs and
outputs.
Check the seed monitor system.
Check the tramline system.
Check the row.
Fill the hopper.
Fill the hopper.
Check whether anything has jammed.
Check whether anything has jammed.
Check the cut-off.
Check the seed flow and ensure that the
chute or shoe have not jammed.
Check the calibration.
Check the calibration.
Perform a calibration test.
Check the charger generator.
Please check the wiring.
Contact the after-sales department.
Contact the after-sales department.
Please check the wiring.
Check whether anything has jammed.
Check whether anything has jammed.
Check the wiring and power supply.
Check the seed monitor system.
Check the seed monitor system.

Publicité

Table des Matières
loading

Table des Matières