Monosem ECU S6400 Notice D'utilisation page 50

Table des Matières

Publicité

4.6 - Alarm message lists
① - Alarm number.
② - Alarm description.
③ - Shows the number of the faulty row.
ID
Alarm message
The system has been stopped.
001
Restart required.
The configuration has been edited. The
002
controller will restart.
Input value too high.
003
Entry too low.
004
Data read or write error in the flash memory
005
or EEPROM.
Data transferred successfully.
006
Configuration error detected.
007
This procedure is not permitted if a task is
008
enabled in the ISOBUS-TC application.
CAN bus speed signal lost.
009
Error when initialising the control-layer
010
configuration.
Several terminals have the same number. Several terminals with the same number
011
Several ISOBUS-TCs have the same
012
number.
1
2
3
ISO ALARMS
Possible cause
The connection with the slave controller
has been lost.
The configuration has been edited.
The input value is too high.
The input value is too low.
An error has occurred when starting up the
controller.
The configuration includes errors.
A task is enabled in the ISOBUS-TC
application.
The wired connection has been lost.
The control-layer has been incorrectly
configured.
are connected to the ISOBUS (function
instance).
Several ISOBUS-TCs with the same
number are connected to the ISOBUS.
50 50
Solution
Restart the controller.
Please wait for the controller to restart.
Input a lower value.
Input a higher value.
Restart the controller.
Please check the configuration.
Disable the task.
Check the wired connection.
Check the configuration.
Change the number in the terminal
(function instance).
Change the number.

Publicité