be assembled by qualified people after the equipment
has been positioned on its place. The assembling
instructions are contained in the envelope that is supplied
inside the packing.
The equipment has to be positioned on its definitive
place and levelled by qualified people.
The unit is equipped with the plug and electrical cable mod.
Schuco. It can also be a British G Type.
The cable has to be connected at 3 mt. max. to a 0,03A
differential fused isolator. NEVER CONNECT THE CABLE TO
MAIN SUPPLY LINE DIRECTLY.
Verify that the power supply voltage is as indicated on the
machine rate plate (fig. C).
Power supply
230 V
220 V
110 V
To ensure correct operation, the maximum voltage variation
must be between +/- 6% of the nominal value.
We recommend to connect the unit to a dedicated circuit and not
to use damaged sockets, extension sockets or multiple
sockets.
In case of incompatibility between the socket and the plug of the
refrigerated cabinet, the plug should be replaced with a suitable
one by a qualified technician.
For units with electric sockets the maximum rating is 1000 W.
During the electrical connection it is forbidden:
- To use adapter sockets or extension sockets.
- To connect other appliances to the same power
socket.
- To pull the electrical cable or the unit to unplug the
equipment from the socket (fig. A).
- To use extension sockets, worn down cables, cables with
damaged or fissured insulation as they are very dangerous:
they could cause sparks, electric shock and fire.
- It is absolutely prohibited to pass cables and con-nect
other sockets under the cabinet.
During the electrical connection verify:
- The power supply cable has to be laid in such a way as to
prevent it from being damaged or becoming hazardous to
people and things.
- In case the power supply cable is damaged, it should
be replaced only by a qualified technician (electrician)
with an equivalent cable.
50 Hz single phase
60 Hz
60 Hz
- The cable of the equipment should be checked regularly. If
it should result that the cable is damaged or deteriorated,
disconnect the equipment and do not use it and let the
cable be replaced with an original replacement part by an
authorised technician.
- Protect the cable in such a way as to prevent twisting or
interlacement with other cables, trample on, crushing,
stretching.
A wrong installation could cause damages to people,
animals or things, for which the manufacturer cannot be
deemed responsible.
12. FIRST CAREFUL CLEANING
DURING THE WHOLE CLEANING OPERATION USE WORKING
GLOVES OF CLASS II TO PROTECT YOUR HANDS ALL
THE TIME AND THE PERSONAL PROTECTIVE EQUIPMENT
ACCORDING TO THE LAW OF YOUR COUNTRY.
Before switching on the unit, take away the protective film that
covers some external and internal parts of the cabinet (for
example display surface, shelves, front decoration panels,
etc.). Clean the refrigerated cabinet thoroughly, both inside and
outside, using warm water (max. 30°C) and a solution of
bicarbonate of soda (1 tea spoon every 2 liters) or white vinegar.
Carefully dry the unit with a soft cloth.
During the cleaning operation it is forbidden:
- To use detergent products, metal pads or abrasive
substances that could damage the aesthetic appearance
of the equipment.
- To use sharp objects (any damage resulting from the
use of these objects will not be covered by warranty).
- To spray water directly on the electric parts and to wet
the electrical parts (fans, lighting, electrical cables, etc.).
- To wash the refrigerated cabinet with water jets.
Once the cleaning is finished, switch the unit on through the
ON/OFF switch and wait until the cabinet reaches the proper
temperature for the products that have to be displayed. It will
take approx. 3 hours for the cabinet to reach the proper
temperature. The products to be displayed will have to be
already cold according to the cabinet temperature.
To switch off the display:
- Set the thermostat to 0.
- Switch off using the ON/OFF switch.
- Turn off the light using the ON/OFF switch.
- Unplug the power cord.
- Wait five minutes.
- Clean the display.
15