Gewiss Easy Manuel D'installation Et D'emploi page 23

Actionneur de commande moteur 1 canal 6 a
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

PROGRAMMING WITH THE EASY BASE UNIT
Programming the stroke and movement times
The motor command actuator uses two settable time options to handle the transitional
shutter positions and the power cut-off to the motor.
• Stroke time, which is the time required for the shutter to close entirely from a
completely open position;
• Movement time, equal to 110% of the stroke time, which is the safety time after
which the power to the electric motor is cut-off.
The stroke time is memorised on the actuator following the procedure below:
1. Open the shutter completely ("all UP").
2. At the same time hold down the 2 local command buttons (figure A): the LEDs will
flash.
3. Within 5 seconds (before the LEDs stop flashing) press the DOWN button and lower
the shutter.
4. When the shutter is completely closed ("all DOWN") press either of the local command
buttons to memorise the stroke time then exit the setup procedure.
Make sure you press the button as soon as the shutter is completely closed in order
to memorise the correct stroke time.
23
E
N
G
L
I
S
H

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Gw 10 767Gw 12 767Gw 14 767

Table des Matières