EN
WARNING
WARNING
WARNING
WARNING
4
IMPROPER USE OF THE EQUIPMENT
NEVER EXCEED MAXIMUM OPERATING PRESSURE AND MAXIMUM OPERATING TEMPERATURE.
Use at more than max. operating pressure can cause explosion of Multi Spray gun resulting in great
danger.
BE SURE TO RELEASE AIR AND FLUID PRESSURE BEFORE CLEANING, DISASSEMBLING OR SERVICING.
If not, remaining pressure can cause bodily injury due to improper operation or scattering cleaning liquid.
In order to release pressure, first stop supply of fluid and thinner to Multi Spray gun.
PROTECTION OF HUMAN BODY
USE IN A WELL-VENTILATED SITE BY USING A SPRAY BOOTH.
If not, poor ventilation can cause organic solvent poisoning and catch fire. If you feel any abnormality
during operation, consult a medical doctor immediately.
ALWAYS WEAR PROTECTIVE GEAR (safety glasses, mask, gloves.)
If not, cleaning liquid, etc., can cause inflammation of eyes and skin.
If you feel something wrong with eyes or skin, immediately see a doctor.
WEAR EARPLUGS IF NECESSARY.
Noise level can exceed 85 dB(A), depending on operating conditions and painting site.
BE SURE TO STOP PUMP, REDUCE AIR AND FLUID PRESSURE DOWN TO 0 AND SECURELY APPLY SAFETY
LOCK OF MULTI SPRAY GUN BEFORE FIT OR REMOVE NOZZLE TIP.
Emission of paint or solvent during operation can cause great danger.
NEVER TRY TO STOP LEAKS BY HAND, WHEN PAINT LEAKS.
In case of leaks, stop pump immediately and reduce paint pressure down to 0 pressure.
High pressure paint emission, can cause severe injury to the body resulting in a great danger for health.
If you feel any abnormality or receive any injury, consult a medical doctor immediately.
Pulling trigger many times during operation, may cause carpal tunnel syndrome.
ALWAYS REST, IN CASE OF TIREDNESS.
OTHER PRECAUTIONS
NEVER ALTER THIS MULTI SPRAY GUN.
If done, it can cause insufficient performance and failure or in extreme cases, explosions.
DO NOT ENTER WORKING AREAS WHERE ROBOTS, RECIPROCATORS, ETC. ARE USED, UNTIL THEY HAVE
BEEN TURNED OFF.
Otherwise they could can cause injury.
NEVER USE THIS GUN TO SPRAY FOODS OR CHEMICALS.
Otherwise foreign substance, could cause corrosion of fluid passages which could adversely affect health.
SECURELY CONNECT FLUID HOSE.
If hose is disconnected during operation, hazardous hose movement and paint ejection will cause severe
bodily injury.
IF SOMETHING GOES WRONG, IMMEDIATELY STOP OPERATION AND FIND THE CAUSE. Do not use again
until you have solved the problem.
NEVER USE SPARE PARTS THAT ARE NOT ANEST IWATA ORIGINALS.
BURST OF FLUID HOSE
NEVER USE CRACKED, DAMAGED, BENT OR CRUSHED FLUID HOSE.
High pressure paint emitted from small hole can pierce an iron plate and cause great danger.
NEVER BEND FLUID HOSE WITH A RADIUS OF LESS THAN PERMITTED BEND RADIUS.
Contact us, or the shop who sold the hose to you, about permitted bend radius. Never put heavy things on
it in order not to damage the hose. If done, hose can explode causing great danger.