Note. In all models of the device, the temporary lack of power caused by a mains power outage or replacing
the battery, does NOT lead to any programming being deleted.
Technical features
Battery-powered TA500
• Power supply: 2 alkaline LR6 penlight AA 1.5V
batteries (not supplied).
• Battery life: More than 1 year.
• Time available for replacement of batteries:
1 minute
• Relay: max. voltage 250 V, max. current 5A with
resistive load (2A with inductive load).
• Type of action: 1B-U.
• Available contacts: 1 NA-NC switch contact.
Available inputs: 1 input for remote control
or for connection of external probe
(maximum cable length 10 metres).
• Temperature range of external probe: from
–30 °C to +60°C.
• Accuracy of internal probe: ≤ ±0.3°C.
• Resolution temperature reading: 0.1°C.
• Accuracy of clock: maximum error ±1 sec/day.
• Range of adjustment: from +3°C to +35°C.
• Protection rating: IP30.
• Operating temperature: from 0 °C to +40 °C.
• Maximum operating relative humidity: 93%
(without condensation).
• Dimensions: 140x92x24.5 mm
• Room temperature measurement interval:
15 seconds.
• Electrical insulation: Class II, reinforced
between accessible parts and terminals,
• Maximum control unit temperature: T40
Mains-powered TA500 230
• Power supply: 230 Vac 50/60Hz
• Consumption: 16mA.
• Autonomous life without power supply:
about 10 hrs.
• Relay: max. voltage 250 V, max. current 5A with
resistive load (2A with inductive load).
• Type of action: 1B-U.
• Available contacts: 1 NA-NC switch contact.
• Accuracy of internal probe: ≤ ±0.5 °C.
• Resolution temperature reading: 0.1°C.
• Accuracy of clock: maximum error ±1 sec/day.
• Range of adjustment: from +3°C to +35°C.
• Protection rating: IP30.
• Operating temperature: from 0 °C to +40 °C.
• Maximum operating relative humidity: 93%
(without condensation).
• Dimensions: 140x92x24.5 mm
• Room temperature measurement interval:
15 seconds.
• Electrical insulation: Class II, reinforced
between accessible parts and terminals,
• Maximum control unit temperature: T40

Publicité

loading

Ce manuel est également adapté pour:

Ta/500 230