Supplemental Characteristics

Supplemental characteristics are not warranted but are descriptions of performance determined
either by design or by type testing. All supplemental characteristics are typical unless otherwise
noted.
Characteristic
Power relay ratings
    Option 500:
    Option 950:
Power relay, mechanical life:
Power relay, hot-switched life:
Sense relay life:
Discharge resistor
    Option 500:
    Option 950:
Regulatory Compliance
    EMC:
    Safety:
Environmental
  Operating environment:
    Temperature range: 1
    Relative humidity:
    Altitude:
    Storage temperature:
Output Terminal Isolation:
AC Input
    Nominal Rating:
    Input Range:
    Power consumption:
Typical Weight
1 Maximum continuous power available is derated at 1% of rating per degree C from 40°C to 55°C
314
500 VDC; 60 ADC
950 VDC; 60 ADC
1,000,000 cycles
10,000 cycles
1,000,000 cycles
25 kΩ, 10 W
97.5 kΩ, 10 W
Complies with European EMC Directive for test and measurement products
Complies with Australian standard and carries C-Tick mark
This ISM device complies with Canadian ICES-001
Cet appareil ISM est conforme à la norme NMB-001 du Canada
Complies with European Low Voltage Directive and carries the CE-marking.
Conforms to US and Canadian safety regulations.
Declarations of Conformity for this product may be downloaded from the Web. Go to
http://regulations.corporate.keysight.com
Indoor use, installation category II (for AC input), pollution degree 2
0°C to 55°C
95% or less (non-condensing)
Up to 2000 meters
-30°C to 70°C
No output terminal may be more than ±950 VDC from any other terminal or chassis ground.
Single phase; 100–240 VAC input, 50-60 Hz
86–264 VAC; 47–63 Hz
150 W
33 lbs (15 kg)
Keysight SD1000A