Thermal protection:
The thermal protection of the unit will kick in if the temperature of the conductors is excessive. In that case, the L05 LED activates and it is not possible
to weld while the temperature remains too high. If the thermal protection kicks in, leave the unit to cool down for 15 minutes.
Unit controls panel :
The settings of the unit can be changed using an SW 8 switch box on the electronic converter. To access the box, it is required to place the metal
case where the 4 buttons and the fuse holder are. This operation must be carried out by a qualified technician and when the unit is disconnected
from the power source.
DIP switch settings
DIP-Switch Einstellungen
1
2
3
4
5
6
7
8
Precisions regarding function SW4 :
This function gives access to totalisators of events that happened when the unit was used and shown as functions Fc1 to Fc6, displayed on the top
screen. Change the function by using buttons 10 and 11.
Function
Description
Torch trigger information test. The bottom screen will display 888 when the trigger is pushed. It will stop displaying when the trigger
Fc1
is released.
Amount of welding cycles performed. Display unit: 1000 cycles. The display follows 3 steps: 3 digits of heavy weights for 2s, 3 digits
Fc2
of light weights for 2s and no information for 2s.
Total amount of time the unit was switched on. Display unit : 1 hour. The display follows 3 steps: 3 digits of heavy weights for 2s, 3
Fc3
digits of light weights for 2s and no information for 2s.
Total amount of time the unit was welding. Display unit : 1 hour. The display follows 3 steps: 3 digits of heavy weights for 2s, 3 digits
Fc4
of light weights for 2s and no information for 2s.
Total number of ocassions where the thermal protection kicked in. Display unit: 1 occasion. The display follows 3 steps: 3 digits of
Fc5
heavy weights for 2s, 3 digits of light weights for 2s and no information for 2s.
Total number of occasions where the overvoltage protection kicked in. Display unit: 1 occasion. The display follows 3 steps: 3 digits
Fc6
of heavy weights for 2s, 3 digits of light weights for 2s and no information for 2s.
AUTOFEED 450
AUTOFEED 450
SW
Display hold on
Displaysperre aktiviert
Welding current display on
Anziege des Strom aktiviert
Wire speed display : m/min
Anziege der Drahtgeschwindigkeit : m/min
Mode diagnostic désactivé
Service mode off
Diagnosemodus deaktiviert
Étalonnage du courant désactivé
Current calibration off
Kalibrierung Strom deaktiviert
Étalonnage de la tension (+) désactivé
Voltage (+) calibration off
Kalibrierung Spannung (+) deaktiviert
Étalonnage de la tension (-) désactivé
Voltage (-) calibration off
Kalibrierung Spannung (-) deaktiviert
Wire speed calibration off
Kalibrierung Drahtgeschwindigkeit deaktiviert
Factory setting :
Werkseinstellungen :
Display hold off
Displaysperre deaktiviert
Welding current display off
Anziege des Strom deaktiviert
Wire speed display : in/min
Anziege der Drahtgeschwindigkeit : in/min
Mode diagnostic activé
Service mode on
Diagnosemodus aktiviert
Étalonnage du courant activé
Current calibration on
Kalibrierung Strom aktiviert
Étalonnage de la tension (+) activé
Voltage (+) calibration on
Kalibrierung Spannung (+) aktiviert
Étalonnage de la tension (-) activé
Voltage (-) calibration on
Kalibrierung Spannung (-) aktiviert
Wire speed calibration on
Kalibrierung Drahtgeschwindigkeit aktiviert
17