iNSTallaTiON

installation
Oversink installation
2
1 Cold water inlet
2 DHW outlet
Note
f Install the appliance flush to the wall. The wall must
have sufficient load bearing capacity.
8.2

Minimum clearances

≥50
f Maintain the minimum clearances to ensure trouble-free op-
eration of the appliance and facilitate maintenance work.
8.3

Water installation

Material losses
!
Carry out all water connection and installation work in
accordance with regulations.
f Flush the water line thoroughly.
Taps
Use appropriate pressure taps. Open vented taps are not per-
missible.
Permissible water line materials
- Cold water inlet line:
Pipes made from galvanised steel, stainless steel, copper or
plastic
- DHW outlet line:
Pipes made from stainless steel, copper or plastic
Material losses
!
If plastic pipework systems are used, take into account
the maximum inlet temperature and the maximum per-
missible pressure.
www.stiebel-eltron.com
1
≥50
Flow rate
f Ensure that the flow rate for switching on the appliance is
achieved.
f If the required flow rate is not achieved when the draw-off
valve is fully open, remove the flow limiter from the cold
water inlet.
If required, the pressure in the water installation can also be raised.
9.
Installation
factory settings
Internal anti-scalding protection in °C
Connected load in kW
Standard installation
Electrical connection from below, installa-
tion on finished walls
Water connection, installation on finished
walls
For further installation options, see chapter "Alternative instal-
lation methods".
9.1

Standard installation on finished walls

Opening the appliance
f Open the appliance by undoing the screw and lifting up the
appliance cover.
Preparing the power cable
A
f Prepare the power cable.
Position on finished walls
Bottom, centre
Bottom, left side of appliance
Bottom, right side of appliance
Top, right side of appliance
Position on unfinished walls
Bottom
Top
DCE-S 6/8
DCE-S 10/12
Plus
Plus
60
@ 220 V
8.0
12.0
@ 230 V
8.7
13.1
@ 240 V
9.6
14.3
DCE-S 6/8
DCE-S 10/12
Plus
Plus
x
x
B
Dimension a
Dimension B
30
120
20
90
20
90
20
80
Dimension a
Dimension B
20
90
20
80
DCE-S Plus |
60
x
x