CONNECTING THE HEAT PUMP TO THE POWER SUPPLY NETWORK
Before connecting to the power
supply network, install a power
supply cord in the heat pump, with a
min. diameter of 1.5 mm
2
F 3G 1.5 mm
). To do this, remove
the protective cover from the heat
pump. The cover is attached using
two screws (Fig. 9). Connecting the
heat pump to the power supply
network
must
take
accordance with the standards for
electric appliances. To comply with
the national installation regulations,
an all poles disconnect switch must
be installed between the heat pump
and the power supply network.
T2
T3
4
6
L
N
9
10
Legend:
T1 - Bar with sensors
T2 - Evaporator – temp. sensor
T3 - Air temperature sensor
1 - 4-way valve
2 - Compressor
4 - Fan
5 - Electric heating element
(2 x 1000 W)
28
2
(H05VV-
place
in
T1
QUART
PROG.
BUZZ1
4
3
K4
2
1
1
2
K5
3
1
4
2
K9
1
3
2
4
K1
3
4
2
K6
5
1
K11
7
8
Fig. 10: Electrical circuit diagram
6 - Thermal cut-out
7 - Magnesium anode
8 - LCD touch screen
9 - Boiler - ground
10 - Housing - ground
Fig. 9: Protective cover
1
1
2
K10
FAS3 FAS2
K3
2
1
K7
2
R
S
C
5

Publicité