Specification

12. Specification

12.1 Dimensions

555
400
228,5
50
e19
e18
e07
Ventilation
e18
Flow
e19
Return
i13
Wall mounting bracket
www.stiebel-eltron.com
110 - 130
BHE 100 Style
Female thread
G 1/2
Female thread
G 1/2
Female thread
G 1/2

12.2 Minimum clearances

≥150
A >320 mm

12.3 Data table

Heating output
Heating output to EN442 (75/65 – 20 °C)
Heating output F/R – T (70/55 – 24 °C)
Heating output F/R – T (50/40 – 24 °C)
Electrical data
Power connection
Connected load
Output, direct heater rod
Output, rapid heater
Dimensions
Height
Width
Depth
Weights
Weight
Versions
Frost protection setting
IP rating
Safety category
Colour
Connections
Connection, heating flow/return
Values
Fill level, heat transfer medium
Max. permissible inlet temperature
Max. operating pressure
Setting range
≥150
BHE 100 Style
233859
W
827
W
598
W
282
1/N ~ 230/240 V
kW
1
kW
1
kW
mm
1695
mm
555
mm
115
kg
34
°C
6
IP24
II
Traffic white, RAL 9016
G 1/2
l
8,734
°C
90
MPa
0.3
°C
6-30