Frost Protection; Operation Within A Dhw/Central Heating System; Shutting Down; Childproofing - Stiebel Eltron BHE 100 Style Utilisation Et Installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 20
OPERATION
Operation
Example:
You would like your bathroom to be heated to the required tem-
perature by 07:00 h.
f On day one, activate the 24 h automatic function at 07:00 h.
f
The appliance will activate the boost function immediately. The
next day, the boost function automatically starts at 06:15 h in order
to heat up the bathroom for 07:00 h.
Interrupting
You can interrupt the boost function at any time without changing
the start time.
f Hold down the boost function button for approximately
f
5 seconds.
The heating indicator flashes twice rapidly.
On the following day the boost function will start again at the
usual start time.
Deactivating
f Hold down the boost function button and press the ON/OFF
f
button twice.
The heating indicator flashes slowly 3-times.
Changing the start time
f Hold down the boost function button and press the ON/OFF
f
button twice.
The heating indicator flashes slowly 3-times. The 24 h automatic
function is disabled.
f Re-activate the 24 h automatic function at the required start
f
time. Hold down the boost function button and press the ON/
OFF button twice.
4.3

Frost protection

The appliance features a frost protection function to ensure that
the room temperature does not fall below 6 °C during a prolonged
period of absence.
f To enable the frost protection function, leave the appliance on
f
and turn the temperature selector to the frost protection setting.
4.4

Operation within a DHW/central heating system

Material losses
!
Only operate the direct heater rod when the radiator has
been filled.
Winter mode
The DHW/central heating system is running. You can control the
appliance temperature via the thermostatic valve installed on site.
Summer mode
When the DHW/central heating system is off the appliance is op-
erated via an integral electric direct heater rod. You can start the
boost and the 24 h automatic function via the user interface.
www.stiebel-eltron.com
4.4.1 Switching between winter and summer mode
Changing from winter to summer mode
f Close the thermostatic valve installed on site.
f
2
1
1 ON indicator for the direct heater rod
2 ON/OFF switch for the direct heater rod
f Press the ON/OFF switch for the direct heater rod to switch it
f
on.
The ON indicator for the direct heater rod lights up.
Changing from summer to winter mode
f Press the ON/OFF switch for the direct heater rod to switch it
f
off.
The ON indicator for the direct heater rod goes off.
f Press the ON/OFF button to turn the appliance off.
f
The ON/OFF indicator goes off. You can control the appliance tem-
perature exclusively via the thermostatic valve installed on site.
Set the thermostatic valve installed on site to the required tem-
perature.
4.5

Shutting down

f Switch the appliance off by pressing the ON/OFF button for
f
the user interface.
The ON/OFF indicator goes off.
f Pull the mains plug out of the wall socket.
f
f If you are operating the appliance within a hot water heating
f
system, close the thermostatic valve installed on site.
4.6

Childproofing

To prevent any unwanted appliance operation, you can lock the
temperature selector or limit its setting range.
f Turn the temperature selector to the required setting.
f
f Lever off the temperature selector using a small screwdriver.
f
1/2 h
1 h
1/4 h
2 h
BHE Style |
15

Publicité

Table des Matières
loading