Connecting The Lines; Bleeding The Pump; Operation - Steinbach SPS 50-1T Notice Originale

Masquer les pouces Voir aussi pour SPS 50-1T:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 33

Connecting the lines

Prepare the following material (not contained in the package contents):
- Pressure line
- Suction line
- Assembly materials for the lines
To connect the lines to the pump and filter vessel as shown in illustration A at the start of this manual,
proceed as follows:
1. Lay the suction line from the pool to the pump.
Keep the suction line as short as possible. Longer lines reduce the pump output.
2. Lay the pressure line from the pump to the filter vessel.
The lines are connected.

Bleeding the pump

1. Establish the water flow to the pump. If necessary, open the shut-off valve or remove the plug in
the suction line.
2. Bleed the pump. To do so, undo the prefilter cover
The prefilter
fills with water.
11
3. Let the prefilter fill completely with water.
4. Close the prefilter cover.
5. Start up the pump.
6. Check the pump and the connections for leaks.
The pump is bled.

Operation

Risk of death when operating the water treatment system during bathing.
Hair or clothing might get sucked into the suction openings of the pool and in extreme cases
trap persons under water and prevent them from surfacing again.
- Never operate water treatment system devices while persons are in the pool.
- Prevent any access to the pool for as long as water treatment system devices are in use.
A damaged device or damaged accessories may cause injuries.
- Check the device and the accessories (see section "Testing").
Pump operation
1. Make sure that all hoses and pipes are correctly connected and that the water level in the pool is at
least 1 to 2" (2.5 to 5 cm) above the opening of the suction line.
2. Check the valve setting of your filter system before you activate the pump.
3. Connect the pump's power plug to the power supply.
The running time display blinks (if a battery is inserted, the last selected running time is displayed).
4. Press the timer button
5. Switch on the pump
The pump starts running at this time and deactivates itself automatically once the selected running
time has expired. The timer activates the pump every day at the same time for the same running
time (once every 24 hours).