b) Setting up a master-slave chain
The effect light can be operated controlled by a DMX controller or in a master-slave chain. Here the in-built
controller of the master unit acts as the controller for the connected Slave DL-LED162 units.
• Connect the DMX OUT port of the master device to the DMX IN port of the first slave device.
• Connect the DMX OUT port of the first slave device to the DMX IN port of the subsequent slave device.
• Proceed as described above with all remaining slave devices.
• Plug an XLR plug with a terminating resistor into the DMX OUT connection of the last slave device (as
described in section „Connection of a DMX controller").
9. Mains connection
The mains socket to which the effect light is connected must be close to the device and easily
accessible to quickly separate the device from the mains voltage in case of an error.
Do not let the mains cable come into contact with other cables.
Be careful when handling mains cables and mains connections. Mains voltage may cause
potentially fatal electric shock.
Make sure that no cables lie around openly. Install cables professionally to prevent accidents.
Before plugging in the mains plug, ensure that the device voltage indicated at the effect light
corresponds to the available mains voltage. Do not connect the device if the indication does not
correspond to the available mains voltage. Incorrect supply voltage may lead to irrepa-rable
damage to the device and danger to the user.
• Connect the low-voltage connector of the mains cable to the POWER mains socket of the device.
• Plug the mains plug of the mains line into a grounded socket.
• Once the device is connected to the mains socket, it takes up operation.
27