The thin part of the connecting cable should be stored and placed where customers cannot touch it.
Plasma Quad Connect
en
Note: Use a 2-core power supply cord (1.0 mm
(1) Loosen terminal screw, and connect power supply cord correctly on the terminal block.
Be careful not to make mis-wiring. Fix the wire to the terminal block securely so that no part of its core is visible,
and no external force is conveyed to the connecting section of the terminal block.
(2) Firmly tighten the terminal screws to prevent them from loosening. After tightening, pull the wires lightly to con-
firm that they do not move.
(3) Fix power supply cord with the cord clamp.
(4) Connect the power supply to the power switch which has a gap of 3 mm or more when open to interrupt the
source power phase.
(When the power switch is shut off, it must interrupt all phases.)
9) Assemble the ELECT_COVER and the COVER_R.
EN-11
Thin part of the connecting cable.
Place this part where customers cannot touch it.
CN105 for INTERFACE
Fix the cable with a clamp.
Fig. 11
) that is up to ø 7 mm and complies with 60245 IEC 57.
2
Thick part of the
connecting cable