6) Remove the screw to remove the COVER_R. (Fig. 8)
screw
7) Remove the screw to remove the ELECT_COVER. (Fig. 9)
8) Connect the cable for CN105 to the indoor unit. (Fig. 10 and Fig. 11)
Note: W hen another interface has already been connected, wire the devices in the following sequence: the existing inter-
face, Plasma Quad Connect, and the indoor unit. Switch the DIP_SW after wiring. (Fig. 10)
Switch the SW11-1 to ON.
Indoor unit
another interface
Indoor unit
Plasma Quad Connect
Fig. 8
Lift the back side of the cover and pull it towards back.
screw
Fig. 9
SW11
Fig. 10
There is a hook inside the cover. Pull the corners
of the cover outward and at the same time pull it
towards you.
screw
Connect the supplied cable to CN105 of the indoor unit.
When another interface is connected, remove the screw and the clamp
first. Disconnect the cable of the interface from the indoor unit and connect
it to CN105 of the Plasma Quad Connect, then fasten the 2 cables with
the removed screw and clamp.
CN105
another interface
en
EN-10