Automatic repositioning
This command is carried out after: a programmer reset; a motor error or an
encoder error. It is indicated by the warning lamps and the indicator light flash-
ing simultaneously for 2 seconds and then switching off for 10 seconds.
After the programmer has been in this condition for 3 minutes it will (after
pre-flashing for 10 seconds) automatically move the gate, slowly, to the
completelyclosedposition(2timesasintheprogrammingprocedure)inorder
to recover the correct position. At this point the programmer will function
normally. To carry out automatic repositioning without waiting for 3 minutes
DISPLAY MODE
Using the PROG button you can access the following functions in
sequence:
- memorising the status of the dip-switches;
- display the status of the command and safety devices;
If the gate is not closed the display will not switch off
and will light up the segments indicating the
command status again.
Memorises the DIP-SWITCH settings and displays
the firmware version.
The segments regarding the command status
(LED "ON" = command active) and safety status
(LED "ON" = safety device at rest) light up.
Activating TB-FTCI-FTCS resets the display time
(additional 10 seconds).
The number of manoeuvres appears on the
display. This number always remains visible until
you change the setting. Once 999999 has been
exceeded the lighting up of the decimal point on
the display equals 1 million + the six figure
number.
In the "test" mode (only activated when the motor has
stopped) it is possible to check the status of the
command and safety devices and carry out eventual
maintenance. The warning lights will activate once,
each
time
a
"TA-TC-TAL-TD-TB-FTCI-FTCS"
command is received.
In
this
mode
you
can
communication by using the external program, which
is to be connected to the CSER connection via cable
(fig. 9).
While communication is active dashes will appear on
the display; after 5 seconds of inactivity you will be
moved back to the "test" mode.
To return to the normal operating mode press the
"test" command again and wait for 10 seconds.
PRESS PROG
PRESS PROG
PRESS PROG
activate
serial
line
PRESS PROG
you may send a (TA, TC, TAL or TD) command to the programmer.
The time count for the repositioning start begins from the moment in which
all safety devices are at rest.
No commands will be accepted during repositioning but the security devices
will cut in and block all movement if they go into alarm.
• To interrupt the repositioning manoeuvre and delay it for another 3 minutes,
press the "PROG" button.
- display the number of manouvres;
- access the "test" mode;
10 sec
Nr. of decimal points lit
10 sec
When the
("TA-TC-TD-TAL-TB-FTCI-FTCS") inputs
are activated the warning lights will light up.
Connect the
programming device
(CSER) and activate it.
5 sec
17
Add to the total
on the display
+ 1.000.000
PRESS PROG
10 sec

Publicité