Fitting the toothed rack
- release the geared motor (fig. 8), lay the first stretch of the toothed rack
on the pinion and fix it to the gate, then fasten down all the other parts
along the entire length of the gate.
- after having fastened the toothed rack, realign the pinion
(play of 1 to 2 mm between the toothed
runner and the pinion) using the position-
ing nuts at the base of the geared motor.
This action will prevent the weight of
the sliding gate from
damaging the unit
when working.
2 mm
6
Attention!
15 mm
You must respect the
distance of 15 mm between the anchor
plate and the base of the motor.
INSTRUCTIONS FOR POSITIONING THE UNIT
7
- The geared motor unit has been assembled in the factory
to be fitted to the LEFT SIDE of the gate (internal view).
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
SCALA: 1:2
To install the motor to the RIGHT of the gate set dip "8"
Drawing number :
of the dip-switch "S1" (fig. 9) to "ON".
DI0342
Product Code :
SL424E
MANUAL RELEASE MECHANISM
Draft :
P.J.Heath
Date :
16-06-2004
Manual release is carried out with the power to the motor interrupted due
CARDIN ELETTRONICA S.p.A - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
to a power failure. To release the gate use the manual release key sup-
plied with the unit. The key should be kept inside the house in an easily
accessible place or stored with the unit itself.
8
7
To release the unit
Remove the cover "A" using a screwdriver and insert the key "B" over
the T-shaped pin, then rotate the key through 90 degrees in the direction
indicated by the arrow "C" (clockwise). This will release the clutch and
separate the gears from the motor allowing you to manually manoeuvre
the gate by pushing lightly on it.
To relock the unit
Follow the above instructions in reverse order rotating the key through 90
degrees in the direction indicated by the arrow "D" (anticlockwise). Close
the release mechanism access cover "A".
SCALA: 1:2
Description :
Drawing number :
DI0130
Sblocco motore
Product Code :
Attention! Never use the manual release mechanism while the
SL4024
Draft :
P.J.Heath
Date :
11-06-98
gate is in operation. If you release the gate and then give a move-
CARDIN ELETTRONICA S.p.A - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
ment command the following symbol appears on the display
Access to the electronic card
To open the cover insert a screwdriver into the slot "G" and turn it through
90° as shown in fig. 8.
Caution! Before opening the cover make sure that the
power has been switched off at the mains.
ON
1 2 3 4 5 6 7 8
Description :
Prodotti Technocity
VISTA DI FIANCO CON MOTORE
F
G
9 0 °
A
C
D
Prodotti Technocity
ELECTRONIC PROGRAMMER
Electronic programmer for a dc motor with an incorporated radio receiver card,
which allows the memorisation of 300 user codes (see "remote control" page 18).
The "rolling code" type decoder uses 433.92 MHz series transmitters.
The motor rotation speed is electronically controlled, starting slowly and increasing
in speed; the speed is reduced as it nears the travel limit so as to enable a control-
led smooth stop.
Programming is carried out using one button and allows you to set the current sensor
and the entire gate travel distance.
The logic carries out position control using an encoder.
The intervention of the anticrush/antidrag sensor during the closing and opening
stages causes a brief (10 cm) travel direction inversion then a block.
ELECTRICAL CONNECTION
Open the "Standard wiring diagram". To make it easier to follow the instructions the
diagram has been placed on the inside of the last page of this manual.
ELECTRONIC CARD DESCRIPTION
B1
Signal buzzer "via radio" mode
CN1
Motor Faston connection
CSER
Serial line connection
D1
Six-segment LED display
S1
Selection dip-switch
E1
Encoder connection
F1
1.6A delayed fuse (230 Vac motor power protection)
F2
3.15A rapid fuse (24V transformer power protection)
F3
10A rapid fuse (motor power protection from the transformer)
F4
10A rapid fuse (motor protection during battery powered operation)
F5
3.15A rapid fuse (24V circuit protection battery powered operation)
J1
Radio channel selection
J2
Enable transmitter memorisation via radio
L1
LED power on
L2
LED battery connection error
L3
LED transmitter code programming
L4
LED undercharged battery error
L5
LED blocking button activated (TB)
L6
LED inverting photocells activated (FTCI)
L7
LED stop photocells (FTCS) or contact safety edge (CSP) activated
L8
LED opening button activated (TA)
L9
LED closing button activated (TC)
L10
LED limited opening button activated (TAL)
B
L11
LED dynamic command activated (TD)
M1
Transmitter code memory module
P1
Transmitter code memorization button (MEMO)
P2
Transmitter code cancellation button (DEL)
P3
Programming button (PROG)
R1
Radio frequency module, 433 MHz for S449 transmitters
LP
Flashing warning lights
LS
Indicator light
FTC-RX Photocell receiver
FTC-TX Photocell transmitter
SEL
Selector switch
TB
Blocking button
TD
Sequential button
ANS
External antenna 433 MHz
• Before connecting the appliance make sure that the voltage and fre-
quency rated on the data plate conform to those of the mains supply.
.
• An all pole trip switch with at least 3 mm between the contacts must
be installed between the unit and the mains supply.
• Don't use cables with aluminium conductors; don't solder the ends
of cables which are to be inserted into the binding posts; use cables
marked T min 85°C and resistant to atmospheric agents.
• The terminal wires must be positioned in such a way that both the
wire and the insulating sheath are tightly fastened (a plastic jubilee clip
is sufficient).
14