IMPORTANT REMARKS
TO REDUCE THE RISK OF SEVERE INJURY OR DEATH READ THE FOLLOWING REMARKS
CAREFULLY BEFORE PROCEEDING WITH THE INSTALLATION. PAY PARTICULAR ATTENTION
TO ALL THE PARAGRAPHS MARKED WITH THE SYMBOL
INSTRUCTIONS COULD COMPROMISE THE CORRECT WORKING ORDER OF THE SYSTEM.
• These instructions are aimed at professionally qualified "INSTALLERS OF
ELECTRICAL EQUIPMENT" and must respect the local standards and
regulations in force. All materials used must be approved and must suit the
environment in which the installation is situated.
• All maintenance operations must be carried out by professionally qualified
technicians.
• This appliance must be used exclusively for the purpose for which it has been
made."i.e.fortheautomationofgatesanddoors".Theunit101/SL424EBSS
can drive sliding gates with weights of up to 400 kg with a maximum travel
distance of 12 m.
• This product and all its relative components has been designed and manu-
factured by Cardin Elettronica who have verified that the product conforms
in every aspect to the safety standards in force.
Any non authorised modifications are to be considered improper and therefore
dangerous. The manufacturer accepts no liability for situations arising from the
use of an electrical installation which does not conform to the local standards
andregulationsinforceandinparticularwhentheearthingcircuitisnotefficient.
• After having installed the device, and before powering up the programmer,
release the gate (manual release mechanism) and move it manually, checking
that it moves smoothly and has no unusual points of resistance.
Caution! The installation of both anti-derailment buffers
is absolutely obligatory.
The programmer can activate the motor automatically.
This is indicated by the warning lights pre-flashing for 10 seconds,
and by the symbol
repositioning" on page 17).
• The programmer is fitted with an electrical input monitoring system, which
is used to block the motor in emergency conditions; however this system is
not active during the first second of each manoeuvre.
Do not therefore attempt to physically block the door during these
stages.
Note: If you need to check the status of the fuses, disconnect the power supply
to the programmer; reconnect it only after having re-inserted the fuse.
Warning! The presence of the electrical input monitoring system
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
does not exclude the need to install photoelectric cells or other
safety devices which are foreseen by the local standards and
regulations in force.
Warning! The geared motor unit has been assembled in the factory
to be fitted to the left side of the gate. Read the paragraph on page
14 "instructions for positioning the unit".
Warning! For the correct operation of the programmer the incor-
porated batteries must be in good condition: the programmer
will lose the position of the gate in case of blackouts when the
batteries are flat, the alarm will sound and automatic repositioning
will take place .
Check the good working order of the batteries every six months
(see page 19 "Battery check").
OVERALL DIMENSIONS
IMPORTANT REMARKS
Q
appearing on the display ("automatic
145
145
. NOT READING THESE IMPORTANT
IMPORTANT SAFETY INSTRUCTIONS
It is the responsibility of the installer to make sure that the following public safety
conditions are satisfied:
1) Ensure that the gate operating installation is far enough away from the main
road to eliminate possible traffic disruptions and that the size of the gate, the
distance from the road and the work cycle speed can in no way interfere,
causing possible traffic hazards.
2) The motor must be installed on the inside of the property and not on the public
side of the gate. The gates must not open onto a public area.
3) The gate operator is designed for use on gates through which vehicles are
passing. Pedestrians should use a separate entrance.
4) Make sure that the end-user is aware that children and/or pets must not be
allowed to play within the area of a gate installation. If possible include this
in the warning signs (see point 6)
5) The gate must be in full view when it is operating therefore controls must be
situated in a position where the operator can see the gate
at all times.
6) At least two warning signs (similar to the example on the
right) should be placed, where they can be easily seen by
the public, in the area of the system of automatic opera-
tion. One inside the property and one on the public side
of the installation. These signs must be indelible and not
hidden by any objects (such as tree branches, decorative
fencing etc.).
7) A correct earth connection is fundamental in order to guarantee the electrical
safety of the machine
8) If you have any questions about the safety of the gate operating system, do
not install the operator. Contact your dealer for assistance.
TECHNICAL DESCRIPTION
• Motor powered with a maximum voltage of 38 Vdc.
• A two-piece shell made of die cast aluminium enclosing the reduction unit and a
pair of steel gears, lubricated with permanently fluid grease.
• The reduction unit stator is made of die cast aluminium and contains worm gear
and a helicoidal crown wheel made of thermoplastic lubricated with permanently
fluid grease.
• Theincorporatedelectronicprogrammercontainsthepowerstage,thelogiccontrol
and the radio receiver decoding module. The power supply is routed to the electron-
ics card via a separate transformer which is housed in the same container.
• Cover in shockproof plastic.
Accessories
106/SLOPC
Toothed rack (dim. 20 mm x 20 mm) in glass fibre with a steel
core for sliding gates. Model with fastening slits above (1 m).
106/SLOPC1 Toothed rack (dim. 20 mm x 20 mm) in glass fibre with a steel
core for sliding gates. Model with fastening slits below (1 m).
106/SLOAC
Toothed rack in galvanised steel, 2 m to be welded.
106/SLOAC2 Toothed rack in galvanised steel, 1 m with slits.
950/XLBS
Contract safety edge, lengths of 1,5 and 3,0 m height 70 mm.
166
42
116
12
IMPORTANT REMARKS
AUTOMATIC OPENING
290
WARNING
KEEP CLEAR
CHILDREN OR PETS MUST NOT
BE ALLOWED TO PLAY ON OR
NEAR THE INSTALLATION
3