13 Device Information

Device information for brine-to-water heat pumps (heating only)
1
Type and order code
2
Design
2.1
Model
2.2
Degree of protection according to EN 60 529
2.3
Installation location
3
Performance data
3.1
Operating temperature limits:
Heating water flow
Cooling, flow
Brine (heat source, heating)
Brine (heat sink, cooling)
Antifreeze
Minimum brine concentration (-13 °C freezing temperature)
3.2
Temperature spread of heating water (flow/return flow) at B0 / W35K
3.3
Heat output / COP
3.4
Cooling capacity / COP
3.5
Sound power level
3.6
Heating water flow with an internal pressure differential of m³/h / Pa
3.7
Free compression of heat circulating pump (level 3)
3.8
Brine throughput with an internal pressure differential
(heat source) of
3.9
Free compression of brine circulating pump (level 3)
3.10 Refrigerant; total filling weight
3.11 Lubricant; total filling weight
4
Dimensions, connections and weight
4.1
Device dimensions without connections
4.2
Device connections to heating system
4.3
Device connections to heat source
4.4
Weight of the transportable unit(s) incl. packing
5
Electrical Connection
5.1
Nominal voltage; fuse protection
5.2
Nominal power consumption
5.3
Starting current with soft starter
Nominal current B0 W35 / cos ϕ
5.4
6
Complies with the European safety regulations
7
Additional model features
7.1
Water in device protected against freezing
7.2
Performance levels
7.3
Controller internal/external
1. This data indicates the size and capacity of the system according to EN 255 and EN 14511. For an analysis of the economic and energy efficiency of the system, both the bivalence
point and the regulation should also be taken into consideration. The specified values, e.g. B10 / W55, have the following meaning: Heat source temperature 10 °C and heating
water flow temperature 55 °C.
2. Note that additional space is required for pipe connections, operation and maintenance.
3. See CE declaration of conformity
4. The heat circulating pump and the heat pump controller must always be ready for operation.
www.dimplex.de
°C
°C
°C
°C
1
at B-5 / W55
kW / ---
1
at B0 / W45
kW / ---
1
at B0 / W50
kW / ---
1
at B0 / W35
kW / ---
at B20 / W8
kW / ---
at B20 / W18
kW / ---
at B10 / W8
kW / ---
at B10 / W18
kW / ---
dB(A)
Pa
m³/h / Pa
Pa
type / kg
type / litres
2
H x W x L mm
Inch
Inch
kg
V / A
1
B0 W35
kW
A
A / ---
4
SI 8MR
SI 10MR
Reversible
Reversible
IP20
IP20
Indoors
Indoors
Up to 55
Up to 55
+7 to +20
+7 to +20
-5 to +25
-5 to +25
+5 to +25
+5 to +25
Monoethylene glycol
Monoethylene glycol
25%
25%
10.6
5.0
9.9
7.5 / 2.0
9.8 / 2.1
8.6 / 2.8
8.8 / 2.8
11.3 / 2.9
9.3 / 4.0
9.1 / 3.9
11.6 / 4.1
9.9 / 4.6
9.8 / 4.5
11.4 / 4.6
12.0 / 5.4
11.9 / 5.2
14.1 / 5.3
9.9 / 5.6
9.8 / 5.4
11.6 / 5.7
12.4 / 6.7
12.2 / 6.6
14.1 / 6.5
54
55
1.55 /
0.75/ 2,300
1.0 / 4,100
9,700
44,700
41,000
2.3 /
1.8 /
3.0 /
25,000
17,000
24,000
36,500
30,300
R407C / 1.3
R407C / 1.5
FV68S / 1.7
FV68S / 1.7
1220 x 640 x 624
1220 x 640 x 624
G 1" a
G 1" a
G 1" a
G 1" a
150
151
230 / 20
230 / 25
2.32
2.33
2.83
38
38
12.5 / 0.8
12.6 / 0.8
15.2 / 0.8
3
3
No
No
1
1
Internal
Internal
13
SI 12TR
Reversible
IP20
Indoors
Up to 55
+7 to +20
-5 to +25
+5 to +25
Monoethylene glycol
25%
5.0
9.9
5.0
9.8 / 2.1
10.8 / 3.0
10.8 / 3.0
11.3 / 2.9
11.4 / 4.0
11.6 / 4.1
11.4 / 4.0
11.3 / 4.4
11.4 / 4.6
11.3 / 4.4
13.9 / 5.2
14.1 / 5.3
13.9 / 5.2
11.4 / 5.5
11.6 / 5.7
11.4 / 5.5
13.8 / 6.3
14.1 / 6.5
13.8 / 6.3
56
1.95 /
1.95 /
1.0 / 4,100
16,000
16,000
41,000
2.5 /
3.0 /
2.5 /
17,000
24,000
17,000
30,300
R407C / 1.4
FV68S / 1.7
1220 x 640 x 624
G 1" a
G 1" a
152
400 / 16
2.85
2.83
2.85
26
15.3 / 0.8
4.8 / 0.8
4.9 / 0.8
3
No
1
Internal
E-9