8654402
Worm Gear shaft. Make sure the Worm Gear shaft is inserted as far as
possible into the Crank, then tighten the Set Screw (Fig. 1).
c.
Use the Socket Head Cap Screw (#13) to attach the Handle Grip (#12)
to the Table Crank. Use a hex key (not supplied) to securely tighten
the Handle Grip.
d.
Loosen the set screw in the
Collar (#91) and remove the
Collar and Rack (#14) from the
Column. The Rack is stowed in
this position only for transit
purposes.
e.
With the long smooth end of the
Rack uppermost, slide the Rack
down through the notch in the
opening in the Table Support
(Fig. 2-1). Engage the Rack into
the Gear Mechanism located on
the inside of the Table Support.
f.
While holding the Rack and the Table Support as assembled, slide
both down onto the Column. Slide the Rack down until the bottom of
the Rack is positioned against the Column Support.
g.
Replace the Collar onto the Column with its beveled side down,
ensuring that the top end of the Rack is engaged in the groove formed
between the Collar and the Column.
IMPORTANT! Make sure the Rack is not pinched and there is a
working clearance between the Rack and Collar.
h.
Tighten the Collar set screw. The Collar must sit evenly on the Column
and fit loosely over the top of the Rack to allow the Rack to move
easily when the Table is rotated around on the Column. Only tighten
the Collar set screw enough to keep the Collar in place on the Column.
Overtightening the set screw may damage the Collar.
i.
Check the Collar for proper adjustment. The Rack should move freely
when the Table is rotated the full 360º around the Column.
12
20 in. Floor-Mount Drill Press
For technical questions call 1-800-665-8685
V 4.0