Electrics
Inputs DIN EN 61131-2
Total current of 24 V sensor supply for all input modules limited to 0.7 A.
Input delay 0 – 1
Input delay 1 – 0
Electrics
Outputs DIN EN 61131-2
Output voltage
Output current
Overload protection
Line length for M8
and M12 connection
Power supply
U
and U
Q1
Q2
AVENTICS | PROFINET-IO | R412015162–BDL–001–AE
9.3
8x input modules, RMV04-8DI_M8
and RMV04-8DI_M12
8 digital inputs, type 3, two-wire proximity switch with a quiescent current
9.4
8x output modules, RMV04-8DO_M8
and RMV04-8DO_M12
For thermal reasons, the outputs may not be loaded with anything above
Technical Data
of max. 2.5 mA can be connected
8 digital outputs
Nominal value 24 V
H signal voltage drop 1.5 V
Nominal value 0.5 A
the nominal current for long periods.
Switches off at 0.6 to 1.2 A
Autom. start-up when load is reduced
Nominal value 24 V
111
3 ms
3 ms
max. 30 m
(+20%/-15%)