Installation

Welder Specifications

Table 1. Welder Specifications
Primary (input) volts
Welding Output
Phase
Frequency
Rated Duty Cycle
Wire Diameter Range

Site Selection

BE SURE TO LOCATE THE WELDER ACCORDING TO THE FOLLOWING GUIDELINES:
• In areas free from moisture and dust;
• In areas with ambient temperature between 30° to 90°F;
• In areas free from oil, steam and corrosive gases;
• In areas not subjected to abnormal vibration or shock;
• In areas not exposed to direct sunlight or rain;
• Place at a distance of 12" or more from walls or similar obstructions that could restrict
natural air flow for cooling.

Power Source Connection

This welder is designed to operate on a properly grounded 230V, 60HZ, single-phase alternating
current (AC) power source fused with a 50A time-delayed fuse or circuit breaker. It is recommended
that a qualified electrician verify the actual voltage at the receptacle into which the welder will be
plugged and confirm that the receptacle is properly fused and grounded. The use of the proper circuit
size can eliminate nuisance circuit breaker tripping when welding.
Do not operate this welder if the actual power source is less than 105 VAC. Contact a qualified
electrician if this problem exists. Improper performance and/or damage to the welder will result if
operated on inadequate or excessive power.
Before you make any electrical connection, make sure that supply voltage and frequency available at
site are those stated in the ratings label of your welder.
The main supply voltage should be within ±10% of the rated main supply voltage. Too low a voltage
may cause poor welding performance. Too high a supply voltage will cause components to overheat
and possibly fail. The welder outlet must be:
• Correctly installed, if necessary, by a qualified electrician;
• Correctly grounded (electrically) in accordance with local regulations;
• Connected to the correct size electric circuit.
NOTE:
• Periodically inspect supply cable for any cracks or exposed wires. If it is not in good
condition, have it repaired by a Service Center.
• Do not violently pull the input power cable to disconnect it from supply outlet.
230 VAC
270A maximum
Single
60Hz
60%
Up to 0.045"
WWW.FORNEYIND.COM