Function
The "Sleep" mode switches on a lower speed level after the
previously set speed level:
When the fan is at speed level 10-12, the fan operates at speed
level 12 for 30 minutes. Then at speed level 9 for 30 minutes.
Then at speed level 6 until the fan is switched off.
If the unit is at speed 7-9 to set the sleep mode, the unit will op-
erate at speed 9 for 30 minutes, then at speed 6 for 30 minutes
until the fan is switched off.
If the fan is in speed levels 1-6, then the fan operates at speed
level 6 until the unit is switched off.
The „ECO" mode allows the fan to rotate at a speed level
depending on the current ambient temperature.
As soon as the ambient temperature reaches 20°C, the fan
starts to run at speed level 6. The higher the ambient temper-
ature is now, the higher the speed level at which the fan rotates.
Temperature
in °C
Speed level
The maximum speed level is reached at >= 26°C
The minimum speed is at <= 19 °C = speed level 1
At temperatures below 20°C the fan switches to the lowest
speed setting (1). If the ambient temperature is 17°C or lower,
the unit automatically switches to standby mode until the
ambient temperature is at least 20°C again.