NOTE: If "INFO" appears on the display window with a code number, perform the
corresponding corrective action.
ERROR
CODE
Received signal too weak/
101
measuring time too long.
102
Received signal too high.
201
Too much background light.
202
Laser beam interrupted.
203
Insufficient power.
301
Temperature too high.
302
Temperature too low.
401
Hardware error.
402
Unknown error.
If the troubleshooting section does not resolve or describe your problem, contact Uline
Customer Service at 1-800-295-5510.
PAGE 5 OF 15
TROUBLESHOOTING
DESCRIPTION
1-800-295-5510
CORRECTIVE ACTION
Use target plate or change target surface.
Target too reflective. Use target plate or change target
surface.
Reduce background light on target area.
Remove obstacle and repeat measurement.
Replace batteries.
Allow device to cool to operating temperature.
Allow device to warm up to operating temperature.
Switch on/off device several times.
Contact Uline Customer Service at 1-800-295-5510.